Breast Imaging 12th International Workshop, IWDM 2014, Gifu City, Japan, June 29 – July 2, 2014. Proceedings /
This book constitutes the refereed proceedings of the 12th International Workshop on Breast Imaging, IWDM 2014, held in Gifu City, Japan, in June/July 2014. The 24 revised full papers and 73 revised poster papers presented together with 6 invited talks were carefully reviewed and selected from 122 s...
Συγγραφή απο Οργανισμό/Αρχή: | |
---|---|
Άλλοι συγγραφείς: | , , |
Μορφή: | Ηλεκτρονική πηγή Ηλ. βιβλίο |
Γλώσσα: | English |
Έκδοση: |
Cham :
Springer International Publishing : Imprint: Springer,
2014.
|
Σειρά: | Lecture Notes in Computer Science,
8539 |
Θέματα: | |
Διαθέσιμο Online: | Full Text via HEAL-Link |
Πίνακας περιεχομένων:
- Virtual Clinical Trials for the Assessment of Novel Breast Screening Modalities
- Computer-Aided Diagnosis for B-Mode, Elastography and Automated Breast Ultrasound
- Measurement and Clinical Use of Breast Density
- Low-Dose Molecular Breast Imaging - Diagnostic and Screening Applications in Women with Dense Breasts
- Will New Technologies Replace Mammography CAD as We Know It?
- Advanced Telecommunications in Breast Imaging – Streamlining Telemammography, Telepathology and Teleoncology Services to Improve Patient Care
- Predicting the Benefit of Using CADe in Screening Mammography
- Modeling Breast Cancer Screening Outcomes
- The Impact of Introducing Full Field Digital Mammography into a Screening Programme
- Fully Automated Nipple Detection in 3D Breast Ultrasound Images
- Breast Imaging with 3D Ultrasound Computer Tomography: Results of a First In-vivo Study in Comparison to MRI Images
- Factors Affecting Agreement between Breast Density Assessment Using Volumetric Methods and Visual Analogue Scales
- Breast Tissue Segmentation and Mammographic Risk Scoring Using Deep Learning
- Optimization of X-Ray Spectra for Dual-Energy Contrast-Enhanced Breast Imaging: Dependency on CsI Detector Scintillator Thickness
- Dose-Saving Potential of Linear- and Non-Linear Energy Weighting in Photon-Counting Spectral Mammography
- Compositional Three-Component Breast Imaging of Fibroadenoma and Invasive Cancer Lesions: Pilot Study
- Potential Usefulness of Presentation of Histological Classifications with Computer-Aided Diagnosis (CAD) Scheme in Differential Diagnosis of Clustered Microcalcifications on Mammograms
- Potential Usefulness of Breast Radiographers’ Reporting as a Second Opinion for Radiologists’ Reading in Digital Mammography
- Effective Detective Quantum Efficiency (eDQE) Measured for a Digital Breast Tomosynthesis System
- Comparison of SNDR, NPWE Model and Human Observer Results for Spherical Densities and Microcalcifications in Real Patient Backgrounds for 2D Digital Mammography and Breast Tomosynthesis
- Assessing Radiologist Performance and Microcalcifications Visualization Using Combined 3D Rotating Mammogram (RM) and Digital Breast Tomosynthesis (DBT)
- Digital Breast Tomosynthesis: Image Quality and Dose Saving of the Synthesized Image
- Patient Specific Dose Calculation Using Volumetric Breast Density for Mammography and Tomosynthesis
- Comparative Performance Evaluation of Contrast-Detail in Full Field Digital Mammography (FFDM) Systems Using Ideal (Hotelling) Observer versus Automated CDMAM Analysis
- Mammographic Density Effect on Readers’ Performance and Visual Search Pattern
- Towards a Quantitative Measure of Radiographic Masking by Dense Tissue in Mammography
- Three Dimensional Dose Distribution Comparison of Simple and Complex Acquisition Trajectories in Dedicated Breast CT – A Monte Carlo Study
- Quantitative MRI Phenotyping of Breast Cancer across Molecular Classification Subtypes
- A Novel Framework for Fat, Glandular Tissue, Pectoral Muscle and Nipple Segmentation in Full Field Digital Mammograms
- Texture-Based Breast Cancer Prediction in Full-Field Digital Mammograms Using the Dual-Tree Complex Wavelet Transform and Random Forest Classification
- Evaluation of a New Design of Contrast-Detail Phantom for Mammography: CDMAM Model 4.0
- Threshold Target Thickness Calculated Using a Model Observer as a Quality Control Metric for Digital Mammography
- Contrast-Enhanced Digital Mammography Lesion Morphology and a Phantom for Performance Evaluation
- Stability of Volumetric Tissue Composition Measured in Serial Screening Mammograms
- Breast Density Classification Based on Volumetric Glandularity Measured by Spectral Mammography
- Is Volumetric Breast Density Related to Body Mass Index, Body Fat Mass, Waist-Hip Ratio, Age and Ethnicity for Malaysian Women?
- Automated Volumetric Breast Density Derived by Statistical Model Approach
- Volumetric Breast Density and Radiographic Parameters
- The Relationship of Volumetric Breast Density to Socio-Economic Status in a Screening Population
- Use of Volumetric Breast Density Measures for the Prediction of Weight and Body Mass Index
- Mammographic Density and Breast Cancer Characteristics
- Managing Tiled Images in Breast Density Measurements
- Reliability of Breast Density Estimation in Follow-Up Mammograms: Repeatability and Reproducibility of a Fully Automated Areal Percent Density Method
- Usefulness of a Combination DBT(Digital Breast Tomosynthesis) and Automated Volume Analysis of Dynamic Contrast-Enhanced Breast (DCEB) MRI in Evaluation of Response to Neoadjuvant Chemotherapy (NAC)
- Clinical Efficacy of Novel Image Processing Techniques in the Framework of Filtered Back Projection (FBP) with Digital Breast Tomosynthesis (DBT)
- Assessment Schemes with Full Field Digital Mammography
- Predicting Triple-Negative Breast Cancer and Axillary Lymph Node Metastasis Using Diagnostic MRI
- Understanding the Role of Correct Lesion Assessment in Radiologists’ Reporting of Breast Cancer
- Realistic Simulation of Breast Tissue Microstructure in Software Anthropomorphic Phantoms
- A Virtual Human Breast Phantom Using Surface Meshes and Geometric Internal Structures
- Characterisation of Screen Detected and Simulated Calcification Clusters in Digital Mammograms
- Development of a Micro-Simulation Model for Breast Cancer to Evaluate the Impacts of Personalized Early Detection Strategies
- Modelling Vascularity in Breast Cancer and Surrounding Stroma Using Diffusion MRI and Intravoxel Incoherent Motion
- Monte Carlo Modeling of the DQE of a-Se X-Ray Detectors for Breast Imaging
- kVp Tool for Digital Mammography Using Commercial Metallic Foils
- Possibility of Exposure Dose Reduction in Contrast Enhanced Spectral Mammography Using Dual Energy Subtraction Technique: A Phantom Study
- A Protocol for Quality Control Testing for Contrast-Enhanced Dual Energy Mammography Systems
- Trends in Mammogram Image Quality, Dose and Screen-Detected Cancer Rates in an Organized Screening Mammography Program
- Power Spectrum Analysis of an Anthropomorphic Breast Phantom Compared to Patient Data in 2D Digital Mammography and Breast Tomosynthesis
- Contrast-Enhanced Digital Mammography Image Quality Evaluation in the Clinic
- BREAST: A Novel Strategy to Improve the Detection of Breast Cancer
- A Regional Web-Based Automated Quality Control Platform
- A European Protocol for Technical Quality Control of Breast Tomosynthesis Systems
- Conventional Mammographic Image Generation Method with Increased Calcification Sensitivity Based on Dual-Energy
- Development of Mammography System Using CdTe Photon Counting Detector for Exposure Dose Reduction - Study of Effectiveness of the Spectrum by Simulation
- Development of Mammography System Using CdTe Photon-Counting Detector for Exposure Dose Reduction - Evaluation of Image Quality in the Prototype System
- Investigation of Dependence on the Object Orientation in Visibility-Contrast Imaging with the X-Ray Talbot-Lau Interferometer
- Development of New Imaging System Based on Grating Interferometry: Preclinical Study in Breast Imaging
- Basic Study on the Development of a High-Resolution Breast CT
- Analysis of Dependence of Detector Position on Detected Scatter Distribution in Dedicated Breast SPECT
- Evaluation of Physical and Psychological Burden of Subjects in Mammography
- Mammographic Image Database (MIDB) and Associated Web-Enabled Software for Research
- Optimizing High Resolution Reconstruction in Digital Breast Tomosynthesis Using Filtered Back Projection
- The Investigation of Different Factors to Optimize the Simulation of 3D Mass Models in Breast Tomosynthesis
- Clinical Evaluation of Dual Mode Tomosynthesis
- Image Quality of Thick Average Intensity Pixel Slabs Using Statistical Artifact Reduction in Breast Tomosynthesis
- Detection of Spiculated Lesions in Digital
- Mammograms Using a Novel Image Analysis Technique
- Spatial Correlation Analysis of Mammograms for Detection of Asymmetric Findings
- Temporal Breast Cancer Risk Assessment Based on Higher-Order Textons
- Invariant Features for Discriminating Cysts from Solid Lesions in Mammography
- Breast Masses Identification through Pixel-Based Texture Classification
- Automated Labeling of Screening Mammograms with Arterial Calcifications
- False Positive Reduction in CADe Using Diffusing Scale Space
- Automated Detection of Architectural Distortion Using Improved Adaptive Gabor Filter
- Detecting Abnormal Mammographic Cases in Temporal Studies Using Image Registration Features
- Analysis of Mammographic Microcalcification Clusters Using Topological Features
- Differentiation of Malignant and Benign Masses on Mammograms Using Radial Local Ternary Pattern
- Statistical Temporal Changes for Breast Cancer Detection: A Preliminary Study
- Comparison of Calcification Cluster Detection by CAD and Human Observers at Different Image Quality Levels
- A Novel Image Enhancement Methodology for Full Field Digital Mammography
- Correlation between Topological Descriptors of the Breast Ductal Network from Clinical Galactograms and Texture Features of Corresponding Mammograms
- Breast Volume Measurement Using a Games Console Input Device
- Towards Spatial Correspondence between Specimen and In-vivo Breast Imaging
- SIFT Texture Description for Understanding Breast Ultrasound Images
- Comparison of Methods for Current-to-Prior Registration of Breast DCE-MRI
- A Study on Mammographic Image Modelling and Classification Using Multiple Databases
- Quasi-3D Display of Lesion Locations Simulated by Two Views of Digital Mammography
- A Shearlet-Based Filter for Low-Dose Mammography
- Evaluation of Human Contrast Sensitivity Functions Used in the Nonprewhitening Model Observer with Eye Filter
- It Is Hard to See a Needle in a Haystack: Modeling Contrast Masking Effect in a Numerica.