Air Flow Management in Raised Floor Data Centers

The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριοι συγγραφείς: Arghode, Vaibhav K. (Συγγραφέας), Joshi, Yogendra (Συγγραφέας)
Συγγραφή απο Οργανισμό/Αρχή: SpringerLink (Online service)
Μορφή: Ηλεκτρονική πηγή Ηλ. βιβλίο
Γλώσσα:English
Έκδοση: Cham : Springer International Publishing : Imprint: Springer, 2016.
Σειρά:SpringerBriefs in Applied Sciences and Technology,
Θέματα:
Διαθέσιμο Online:Full Text via HEAL-Link
LEADER 02968nam a22005415i 4500
001 978-3-319-25892-8
003 DE-He213
005 20170519114750.0
007 cr nn 008mamaa
008 151123s2016 gw | s |||| 0|eng d
020 |a 9783319258928  |9 978-3-319-25892-8 
024 7 |a 10.1007/978-3-319-25892-8  |2 doi 
040 |d GrThAP 
050 4 |a TH1-9745 
072 7 |a KJMV4  |2 bicssc 
072 7 |a BUS093000  |2 bisacsh 
082 0 4 |a 658.2  |2 23 
100 1 |a Arghode, Vaibhav K.  |e author. 
245 1 0 |a Air Flow Management in Raised Floor Data Centers  |h [electronic resource] /  |c by Vaibhav K. Arghode, Yogendra Joshi. 
264 1 |a Cham :  |b Springer International Publishing :  |b Imprint: Springer,  |c 2016. 
300 |a XX, 72 p. 39 illus., 3 illus. in color.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a SpringerBriefs in Applied Sciences and Technology,  |x 2191-530X 
505 0 |a 1. Introduction -- 2. Metrology Tools -- 3. Cooling Air Delivery Through Perforated Tiles -- 4. Cold Aisle Containment -- 5. Other Air Delivery Schemes. 
520 |a The Brief discuss primarily two aspects of air flow management in raised floor data centers. Firstly, cooling air delivery through perforated tiles will be examined and influence of the tile geometry on flow field development and hot air entrainment above perforated tiles will be discussed. Secondly, the use of cold aisle containment to physically separate hot and cold regions, and minimize hot and cold air mixing will be presented. Both experimental investigations and computational efforts are discussed and development of computational fluid dynamics (CFD) based models for simulating air flow in data centers is included. In addition, metrology tools for facility scale air velocity and temperature measurement, and air flow rate measurement through perforated floor tiles and server racks are examined and the authors present thermodynamics-based models to gauge the effectiveness and importance of air flow management schemes in data centers. 
650 0 |a Engineering. 
650 0 |a Computer hardware. 
650 0 |a Thermodynamics. 
650 0 |a Heat engineering. 
650 0 |a Heat transfer. 
650 0 |a Mass transfer. 
650 0 |a Facility management. 
650 1 4 |a Engineering. 
650 2 4 |a Facility Management. 
650 2 4 |a Energy Efficiency. 
650 2 4 |a Engineering Thermodynamics, Heat and Mass Transfer. 
650 2 4 |a Computer Hardware. 
700 1 |a Joshi, Yogendra.  |e author. 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer eBooks 
776 0 8 |i Printed edition:  |z 9783319258904 
830 0 |a SpringerBriefs in Applied Sciences and Technology,  |x 2191-530X 
856 4 0 |u http://dx.doi.org/10.1007/978-3-319-25892-8  |z Full Text via HEAL-Link 
912 |a ZDB-2-ENG 
950 |a Engineering (Springer-11647)