Image Analysis for Ophthalmological Diagnosis Image Processing of Corvis® ST Images Using Matlab® /

This monograph focuses on the use of analysis and processing methods for images from the Corvis® ST tonometer. The presented analysis is associated with the quantitative, repeatable and fully automatic evaluation of the response of the eye, eyeball and cornea to an air-puff. All the described algori...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριος συγγραφέας: Koprowski, Robert (Συγγραφέας)
Συγγραφή απο Οργανισμό/Αρχή: SpringerLink (Online service)
Μορφή: Ηλεκτρονική πηγή Ηλ. βιβλίο
Γλώσσα:English
Έκδοση: Cham : Springer International Publishing : Imprint: Springer, 2016.
Έκδοση:1st ed. 2016.
Σειρά:Studies in Computational Intelligence, 631
Θέματα:
Διαθέσιμο Online:Full Text via HEAL-Link
LEADER 02714nam a22004935i 4500
001 978-3-319-29546-6
003 DE-He213
005 20160205022354.0
007 cr nn 008mamaa
008 160203s2016 gw | s |||| 0|eng d
020 |a 9783319295466  |9 978-3-319-29546-6 
024 7 |a 10.1007/978-3-319-29546-6  |2 doi 
040 |d GrThAP 
050 4 |a Q342 
072 7 |a UYQ  |2 bicssc 
072 7 |a COM004000  |2 bisacsh 
082 0 4 |a 006.3  |2 23 
100 1 |a Koprowski, Robert.  |e author. 
245 1 0 |a Image Analysis for Ophthalmological Diagnosis  |h [electronic resource] :  |b Image Processing of Corvis® ST Images Using Matlab® /  |c by Robert Koprowski. 
250 |a 1st ed. 2016. 
264 1 |a Cham :  |b Springer International Publishing :  |b Imprint: Springer,  |c 2016. 
300 |a XIII, 125 p. 73 illus., 25 illus. in color.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a Studies in Computational Intelligence,  |x 1860-949X ;  |v 631 
505 0 |a Introduction -- Image pre-processing -- Main Image processing -- Additional Image Processing and Measurement -- Impact of Image Acquisition and Selection of Algorithm Parameters on the Results -- Summary of Measured Features -- Conclusions. 
520 |a This monograph focuses on the use of analysis and processing methods for images from the Corvis® ST tonometer. The presented analysis is associated with the quantitative, repeatable and fully automatic evaluation of the response of the eye, eyeball and cornea to an air-puff. All the described algorithms were practically implemented in MATLAB®. The monograph also describes and provides the full source code designed to perform the discussed calculations. As a result, this monograph is intended for scientists, graduate students and students of computer science and bioengineering as well as doctors wishing to expand their knowledge of modern diagnostic methods assisted by various image analysis and processing methods. 
650 0 |a Engineering. 
650 0 |a Ophthalmology. 
650 0 |a Artificial intelligence. 
650 0 |a Computational intelligence. 
650 1 4 |a Engineering. 
650 2 4 |a Computational Intelligence. 
650 2 4 |a Artificial Intelligence (incl. Robotics). 
650 2 4 |a Ophthalmology. 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer eBooks 
776 0 8 |i Printed edition:  |z 9783319295459 
830 0 |a Studies in Computational Intelligence,  |x 1860-949X ;  |v 631 
856 4 0 |u http://dx.doi.org/10.1007/978-3-319-29546-6  |z Full Text via HEAL-Link 
912 |a ZDB-2-ENG 
950 |a Engineering (Springer-11647)