Functional Hemodynamic Monitoring

Hemodynamic monitoring is one of the major diagnostic tools available in the acute care setting to diagnose cardiovascular insufficiency and monitor changes over time in response to interventions. However, the rationale and efficacy of hemodynamic monitoring to affect outcome has come into question....

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Συγγραφή απο Οργανισμό/Αρχή: SpringerLink (Online service)
Άλλοι συγγραφείς: Pinsky, Michael R. (Επιμελητής έκδοσης), Payen, Didier (Επιμελητής έκδοσης)
Μορφή: Ηλεκτρονική πηγή Ηλ. βιβλίο
Γλώσσα:English
Έκδοση: Berlin, Heidelberg : Springer Berlin Heidelberg, 2005.
Σειρά:Update in Intensive Care and Emergency Medicine, 42
Θέματα:
Διαθέσιμο Online:Full Text via HEAL-Link
LEADER 04549nam a22004695i 4500
001 978-3-540-26900-7
003 DE-He213
005 20151204140619.0
007 cr nn 008mamaa
008 100301s2005 gw | s |||| 0|eng d
020 |a 9783540269007  |9 978-3-540-26900-7 
024 7 |a 10.1007/b138257  |2 doi 
040 |d GrThAP 
050 4 |a RC681-688.2 
072 7 |a MJD  |2 bicssc 
072 7 |a MED010000  |2 bisacsh 
082 0 4 |a 616.12  |2 23 
245 1 0 |a Functional Hemodynamic Monitoring  |h [electronic resource] /  |c edited by Michael R. Pinsky, Didier Payen. 
264 1 |a Berlin, Heidelberg :  |b Springer Berlin Heidelberg,  |c 2005. 
300 |a XIV, 422 p.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a Update in Intensive Care and Emergency Medicine,  |x 0933-6788 ;  |v 42 
505 0 |a Functional Hemodynamic Monitoring: Foundations and Future -- Therapeutic goals -- Defining Hemodynamic Instability -- Determinants of Blood Flow and Organ Perfusion -- Determining Effectiveness of Regional Perfusion -- Microcirculatory and Mitochondrial Distress Syndrome (MMDS): A New Look at Sepsis -- ‘Adequate’ Hemodynamics: A Question of Time? -- Limits and Applications of Hemodynamic Monitoring -- Arterial Pressure: A Personal View -- Central Venous Pressure: Uses and Limitations -- Pulmonary Artery Occlusion Pressure: Measurement, Significance, and Clinical Uses -- Cardiac Output by Thermodilution and Arterial Pulse Contour Techniques -- Clinical Value of Intrathoracic Volumes from Transpulmonary Indicator Dilution -- Methodology and Value of Assessing Extravascular Lung Water -- Arterial Pulse Contour Analysis: Applicability to Clinical Routine -- Arterial Pulse Power Analysis: The LiDCO? plus System -- Esophageal Doppler monitoring -- Splanchnic Blood Flow -- Measurement of Oxygen Derived Variables and Cardiac Performance -- Microcirculatory Blood Flow: Videomicroscopy -- Mixed Venous Oxygen Saturation (SvO2) -- Central Venous Oxygen Saturation (ScvO2) -- DO2/VO2 relationships -- Cardiac Preload Evaluation Using Echocardiographic Techniques -- Right Ventricular End-Diastolic Volume -- Assessment of Fluid Responsiveness -- Fluid Therapy of Tissue Hypoperfusion -- The Use of Central Venous Pressure in Critically Ill Patients -- Arterial Pressure Variation during Positive-pressure Ventilation -- Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising -- Development of Treatment Algorithms -- Standardization of Care by Defining Endpoints of Resuscitation -- Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling -- Cost Effectiveness of Monitoring Techniques. 
520 |a Hemodynamic monitoring is one of the major diagnostic tools available in the acute care setting to diagnose cardiovascular insufficiency and monitor changes over time in response to interventions. However, the rationale and efficacy of hemodynamic monitoring to affect outcome has come into question. We now have increasing evidence that outcome from critical illness can be improved by focused resuscitation based on existing hemodynamic monitoring, whereas non-specific aggressive resuscitation impairs survival. Thus, this book frames hemodynamic monitoring into a functional perspective wherein hemodynamic variables and physiology interact to derive performance and physiological reserve estimates that themselves drive treatment. This philosophy, as well as the limitations and applications of common and evolving hemodynamic measures and their focused use in the care of critically ill patients are discussed, relevant to one underlying truth: No monitoring device, no matter how simple or sophisticated, will improve patient-centered outcomes useless coupled to a treatment which, itself, improves outcome. 
650 0 |a Medicine. 
650 0 |a Critical care medicine. 
650 0 |a Cardiology. 
650 1 4 |a Medicine & Public Health. 
650 2 4 |a Cardiology. 
650 2 4 |a Intensive / Critical Care Medicine. 
700 1 |a Pinsky, Michael R.  |e editor. 
700 1 |a Payen, Didier.  |e editor. 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer eBooks 
776 0 8 |i Printed edition:  |z 9783540223498 
830 0 |a Update in Intensive Care and Emergency Medicine,  |x 0933-6788 ;  |v 42 
856 4 0 |u http://dx.doi.org/10.1007/b138257  |z Full Text via HEAL-Link 
912 |a ZDB-2-SME 
950 |a Medicine (Springer-11650)