Inductive Powering Basic Theory and Application to Biomedical Systems /

Inductive powering has been a reliable and simple method for many years to wirelessly power devices over relatively short distances, from a few centimetres to a few feet. Examples are found in biomedical applications, such as cochlear implants; in RFID, such as smart cards for building access contro...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Συγγραφή απο Οργανισμό/Αρχή: SpringerLink (Online service)
Άλλοι συγγραφείς: Schuylenbergh, Koenraad Van (Επιμελητής έκδοσης), Puers, Robert (Επιμελητής έκδοσης)
Μορφή: Ηλεκτρονική πηγή Ηλ. βιβλίο
Γλώσσα:English
Έκδοση: Dordrecht : Springer Netherlands, 2009.
Σειρά:Analog Circuits and Signal Processing
Θέματα:
Διαθέσιμο Online:Full Text via HEAL-Link
LEADER 03587nam a22004935i 4500
001 978-90-481-2412-1
003 DE-He213
005 20151125151059.0
007 cr nn 008mamaa
008 100301s2009 ne | s |||| 0|eng d
020 |a 9789048124121  |9 978-90-481-2412-1 
024 7 |a 10.1007/978-90-481-2412-1  |2 doi 
040 |d GrThAP 
050 4 |a TK7888.4 
072 7 |a TJFC  |2 bicssc 
072 7 |a TEC008010  |2 bisacsh 
082 0 4 |a 621.3815  |2 23 
245 1 0 |a Inductive Powering  |h [electronic resource] :  |b Basic Theory and Application to Biomedical Systems /  |c edited by Koenraad Van Schuylenbergh, Robert Puers. 
264 1 |a Dordrecht :  |b Springer Netherlands,  |c 2009. 
300 |a XVI, 223 p.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
490 1 |a Analog Circuits and Signal Processing 
505 0 |a An introduction on telemetry -- The concepts of inductive powering -- Exact link formulaae -- Primary coil drivers -- Optimisation of the driven inductive link -- Automatic link tuning. 
520 |a Inductive powering has been a reliable and simple method for many years to wirelessly power devices over relatively short distances, from a few centimetres to a few feet. Examples are found in biomedical applications, such as cochlear implants; in RFID, such as smart cards for building access control; and in consumer devices, such as electrical toothbrushes. Device sizes shrunk considerably the past decades, demanding accurate design tools to obtain reliable link operation in demanding environments. With smaller coil sizes, the link efficiency drops dramatically to a point where the commonly used calculation methods become invalid. Inductive Powering: Basic Theory and Application to Biomedical Systems is a complete reference for the inductive link designer. It bundles the information scattered throughout literature into a set of consistent formulations allowing engineers to grasp the calculus in full clarity. A general formalism is given for a wide array of applications, ranging from strong to very weak coil coupling. Without loosing universal applicability, the book then focuses on weak coupling (k < 1%) where the existing approximate formulae fail, and demonstrates that the design of the coil driver must be included in the optimisation flow. It provides step-by-step instructions that boost the performance of links originally confined to some microwatts, to several milliwatts without increasing the dimensions. The book lists all design equations and topology alternatives to successfully build an inductive power and data link for your specific application. It also contains practical guidelines to expand the external driver with a servomechanism that automatically tunes itself to varying coupling and load conditions. 
650 0 |a Engineering. 
650 0 |a Engineering design. 
650 0 |a Electrical engineering. 
650 0 |a Electronic circuits. 
650 1 4 |a Engineering. 
650 2 4 |a Circuits and Systems. 
650 2 4 |a Electrical Engineering. 
650 2 4 |a Engineering Design. 
700 1 |a Schuylenbergh, Koenraad Van.  |e editor. 
700 1 |a Puers, Robert.  |e editor. 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer eBooks 
776 0 8 |i Printed edition:  |z 9789048124114 
830 0 |a Analog Circuits and Signal Processing 
856 4 0 |u http://dx.doi.org/10.1007/978-90-481-2412-1  |z Full Text via HEAL-Link 
912 |a ZDB-2-ENG 
950 |a Engineering (Springer-11647)