A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices Three-Electrodes Amperometric Biosensor Approach /

A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices presents the conception and prototype realization of a Self-Powered architecture for subcutaneous detector devices. The architecture is designed to work as a true/false (event detector) or threshold level alarm of som...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριοι συγγραφείς: Colomer-Farrarons, Jordi (Συγγραφέας), Miribel-Català, Pere Lluís (Συγγραφέας)
Συγγραφή απο Οργανισμό/Αρχή: SpringerLink (Online service)
Μορφή: Ηλεκτρονική πηγή Ηλ. βιβλίο
Γλώσσα:English
Έκδοση: Dordrecht : Springer Netherlands : Imprint: Springer, 2011.
Έκδοση:1.
Θέματα:
Διαθέσιμο Online:Full Text via HEAL-Link
LEADER 03157nam a22005055i 4500
001 978-94-007-0686-6
003 DE-He213
005 20151125221833.0
007 cr nn 008mamaa
008 110216s2011 ne | s |||| 0|eng d
020 |a 9789400706866  |9 978-94-007-0686-6 
024 7 |a 10.1007/978-94-007-0686-6  |2 doi 
040 |d GrThAP 
050 4 |a TK7867-7867.5 
072 7 |a TJFC  |2 bicssc 
072 7 |a TJFD5  |2 bicssc 
072 7 |a TEC008010  |2 bisacsh 
082 0 4 |a 621.3815  |2 23 
100 1 |a Colomer-Farrarons, Jordi.  |e author. 
245 1 2 |a A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices  |h [electronic resource] :  |b Three-Electrodes Amperometric Biosensor Approach /  |c by Jordi Colomer-Farrarons, Pere Lluís Miribel-Català. 
250 |a 1. 
264 1 |a Dordrecht :  |b Springer Netherlands :  |b Imprint: Springer,  |c 2011. 
300 |a XI, 163 p.  |b online resource. 
336 |a text  |b txt  |2 rdacontent 
337 |a computer  |b c  |2 rdamedia 
338 |a online resource  |b cr  |2 rdacarrier 
347 |a text file  |b PDF  |2 rda 
505 0 |a Preface / Abstract. Abbreviations -- 1 Introduction -- 2 Energy Harvesting (Multi Harvesting Power Chip) -- 3 Biomedical Integrated Instrumentation -- 4 CMOS Front-End Architecture for In-Vivo Biomedical Subcutaneous Detection Devices -- 5 Conclusions and Future Work -- 5.1 Conclusions -- 5.2 Future Work -- Appendix 1 -- Appendix.-. 2. Appendix 3. 
520 |a A CMOS Self-Powered Front-End Architecture for Subcutaneous Event-Detector Devices presents the conception and prototype realization of a Self-Powered architecture for subcutaneous detector devices. The architecture is designed to work as a true/false (event detector) or threshold level alarm of some substances, ions, etc... that are detected through a three-electrodes amperometric BioSensor approach. The device is envisaged as a Low-Power subcutaneous implantable application powered by an inductive link, one emitter antenna at the external side of the skin and the receiver antenna under the skin. The sensor is controlled with a Potentiostat circuit and then, a post-processing unit detects the desired levels and activates the transmission via a backscattering method by the inductive link. All the instrumentation, except the power module, is implemented in the so called BioChip. Following the idea of the powering link to harvest energy of the magnetic induced link at the implanted device, a Multi-Harvesting Power Chip (MHPC) has been also designed. 
650 0 |a Physics. 
650 0 |a Solid state physics. 
650 0 |a Electronic circuits. 
650 0 |a Biomedical engineering. 
650 1 4 |a Physics. 
650 2 4 |a Electronic Circuits and Devices. 
650 2 4 |a Biomedical Engineering. 
650 2 4 |a Circuits and Systems. 
650 2 4 |a Solid State Physics. 
700 1 |a Miribel-Català, Pere Lluís.  |e author. 
710 2 |a SpringerLink (Online service) 
773 0 |t Springer eBooks 
776 0 8 |i Printed edition:  |z 9789400706859 
856 4 0 |u http://dx.doi.org/10.1007/978-94-007-0686-6  |z Full Text via HEAL-Link 
912 |a ZDB-2-ENG 
950 |a Engineering (Springer-11647)