ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ
The vertical geothermal systems are preferred in those cases where the modernization of air-conditioning in a building is necessary (heating-cooling-water heating) and where there is a scarcity of available land because it does not require large coverage areas. To calculate the required length of ge...
Main Authors: | , , , , , |
---|---|
Format: | 7 |
Language: | Greek |
Published: |
2016
|
Subjects: | |
Online Access: | http://localhost:8080/jspui/handle/11419/4777 |
id |
kallipos-11419-4777 |
---|---|
record_format |
dspace |
spelling |
kallipos-11419-47772021-07-11T20:17:12Z ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ VERTICAL GEOTHERMAL SYSTEMS Vrachopoulos, Michalis Koukou, Maria Karytsas, Konstantinos Βραχόπουλος, Μιχάλης Κούκου, Μαρία Καρύτσας, Κωνσταντίνος ΚΑΝΟΝΙΚΗ ΓΕΩΘΕΡΜΙΑ ΓΕΩΘΕΡΜΙΚΟΙ ΕΝΑΛΛΑΚΤΕΣ ΓΕΩΘΕΡΜΙΚΕΣ ΑΝΤΛΙΕΣ ΘΕΡΜΟΤΗΤΑΣ Normal Geothermy Geothermal Heat Exchangers Geothermal Heat Pumps The vertical geothermal systems are preferred in those cases where the modernization of air-conditioning in a building is necessary (heating-cooling-water heating) and where there is a scarcity of available land because it does not require large coverage areas. To calculate the required length of geothermal heat exchangers international standards exist, instructions and manuals which are presented in this chapter. For dimensioning at given load of heating and/or cooling, there are various methods for both smaller and larger projects that are presented together with the restrictions governing their application. The distribution of winter and summer air conditioning loads should cover geothermal installation is a key element for the design and sizing provisions should cover the maximum need loads throughout the year. Also, the classification of vertical geothermal heat exchangers in categories is presented. Concluding, information concerning the construction of vertical systems is provided. Τα κατακόρυφα γεωθερμικά συστήματα προτιμούνται σε εκείνες τις περιπτώσεις που γίνεται εκσυγχρονισμός των εγκαταστάσεων κλιματισμού ενός κτηρίου (θέρμανση-δροσισμός-παραγωγή ζεστού νερού) και όπου υπάρχει στενότητα διαθέσιμου εδάφους γιατί δεν απαιτεί μεγάλες εκτάσεις κάλυψης. Για τον υπολογισμό του απαιτούμενου μήκους των γεωεναλλακτών διεθνώς υπάρχουν πρότυπα, οδηγίες και εγχειρίδια τα οποία και παρουσιάζονται σε αυτό το κεφάλαιο. Για τη διαστασιολόγηση τους σε δεδομένο φορτίο θέρμανσης ή/και ψύξης, υπάρχουν διάφορες μέθοδοι, τόσο για μικρότερα όσο και για μεγαλύτερα έργα οι οποίες παρουσιάζονται μαζί με τους περιορισμούς που διέπουν την εφαρμογή τους. Η κατανομή των φορτίων χειμερινού και θερινού κλιματισμού που πρέπει να καλύψει η γεωθερμική εγκατάσταση είναι βασικό στοιχείο του σχεδιασμού και η επιλογή του μεγέθους των διατάξεων πρέπει να καλύπτει τη μέγιστη ανάγκη σε φορτία σε όλη τη διάρκεια του έτους. Επίσης, παρουσιάζεται η ταξινόμηση των κατακόρυφων γεωεναλλακτών σε κατηγορίες με βάση το πώς γίνεται η συναλλαγή θερμότητας από τα κανάλια ροής στη γεωμετρία της διατομής τους. Ολοκληρώνοντας, παρέχονται πληροφορίες που αφορούν στην κατασκευή κατακόρυφων συστημάτων και στις διαδικασίες ελέγχου πριν και μετά τη λειτουργία τους. 2016-03-01T16:30:09Z 2021-07-09T14:25:51Z 2016-03-01T16:30:09Z 2021-07-09T14:25:51Z 2016-03-01 7 http://localhost:8080/jspui/handle/11419/4777 el 1 24 application/pdf |
institution |
Kallipos |
collection |
DSpace |
language |
Greek |
topic |
ΚΑΝΟΝΙΚΗ ΓΕΩΘΕΡΜΙΑ ΓΕΩΘΕΡΜΙΚΟΙ ΕΝΑΛΛΑΚΤΕΣ ΓΕΩΘΕΡΜΙΚΕΣ ΑΝΤΛΙΕΣ ΘΕΡΜΟΤΗΤΑΣ Normal Geothermy Geothermal Heat Exchangers Geothermal Heat Pumps |
spellingShingle |
ΚΑΝΟΝΙΚΗ ΓΕΩΘΕΡΜΙΑ ΓΕΩΘΕΡΜΙΚΟΙ ΕΝΑΛΛΑΚΤΕΣ ΓΕΩΘΕΡΜΙΚΕΣ ΑΝΤΛΙΕΣ ΘΕΡΜΟΤΗΤΑΣ Normal Geothermy Geothermal Heat Exchangers Geothermal Heat Pumps Vrachopoulos, Michalis Koukou, Maria Karytsas, Konstantinos Βραχόπουλος, Μιχάλης Κούκου, Μαρία Καρύτσας, Κωνσταντίνος ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ |
description |
The vertical geothermal systems are preferred in those cases where the modernization of air-conditioning in a building is necessary (heating-cooling-water heating) and where there is a scarcity of available land because it does not require large coverage areas. To calculate the required length of geothermal heat exchangers international standards exist, instructions and manuals which are presented in this chapter. For dimensioning at given load of heating and/or cooling, there are various methods for both smaller and larger projects that are presented together with the restrictions governing their application. The distribution of winter and summer air conditioning loads should cover geothermal installation is a key element for the design and sizing provisions should cover the maximum need loads throughout the year. Also, the classification of vertical geothermal heat exchangers in categories is presented. Concluding, information concerning the construction of vertical systems is provided. |
format |
7 |
author |
Vrachopoulos, Michalis Koukou, Maria Karytsas, Konstantinos Βραχόπουλος, Μιχάλης Κούκου, Μαρία Καρύτσας, Κωνσταντίνος |
author_facet |
Vrachopoulos, Michalis Koukou, Maria Karytsas, Konstantinos Βραχόπουλος, Μιχάλης Κούκου, Μαρία Καρύτσας, Κωνσταντίνος |
author_sort |
Vrachopoulos, Michalis |
title |
ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ |
title_short |
ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ |
title_full |
ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ |
title_fullStr |
ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ |
title_full_unstemmed |
ΚΑΤΑΚΟΡΥΦΑ ΓΕΩΘΕΡΜΙΚΑ ΣΥΣΤΗΜΑΤΑ |
title_sort |
κατακορυφα γεωθερμικα συστηματα |
publishDate |
2016 |
url |
http://localhost:8080/jspui/handle/11419/4777 |
work_keys_str_mv |
AT vrachopoulosmichalis katakoryphageōthermikasystēmata AT koukoumaria katakoryphageōthermikasystēmata AT karytsaskonstantinos katakoryphageōthermikasystēmata AT brachopoulosmichalēs katakoryphageōthermikasystēmata AT koukoumaria katakoryphageōthermikasystēmata AT karytsaskōnstantinos katakoryphageōthermikasystēmata AT vrachopoulosmichalis verticalgeothermalsystems AT koukoumaria verticalgeothermalsystems AT karytsaskonstantinos verticalgeothermalsystems AT brachopoulosmichalēs verticalgeothermalsystems AT koukoumaria verticalgeothermalsystems AT karytsaskōnstantinos verticalgeothermalsystems |
_version_ |
1771301343201329152 |