Institutional patient dose levels in multislice computed tomography examinations
Computed tomography (CT) is a major source of radiation patient dose from medical exposure. During the last years CT examinations have increased a lot, so there is need for optimization of the patient dose. In this study the institutional doses for CT examinations for head, chest, abdomen and chest/...
Κύριος συγγραφέας: | |
---|---|
Άλλοι συγγραφείς: | |
Μορφή: | Thesis |
Γλώσσα: | English |
Έκδοση: |
2017
|
Θέματα: | |
Διαθέσιμο Online: | http://hdl.handle.net/10889/10609 |
id |
nemertes-10889-10609 |
---|---|
record_format |
dspace |
institution |
UPatras |
collection |
Nemertes |
language |
English |
topic |
Computed tomography Institutional doses Υπολογιστική τομογραφία Δόση ασθενών 616.075 722 |
spellingShingle |
Computed tomography Institutional doses Υπολογιστική τομογραφία Δόση ασθενών 616.075 722 Μόκα, Άλκηστη Institutional patient dose levels in multislice computed tomography examinations |
description |
Computed tomography (CT) is a major source of radiation patient dose from medical exposure. During the last years CT examinations have increased a lot, so there is need for optimization of the patient dose. In this study the institutional doses for CT examinations for head, chest, abdomen and chest/abdomen, in the University Hospital of Patras are presented. The systems that have been used were Toshiba Aquilion Prime (80 slices) and General Electric Lightspeed 16 (16 slices). Totally four hundred patients participated in this study, fifty of each examination and system.
Τhe patient characteristics (age, sex, body mass index (BMI)) were recorded. To calculate the patient dose the dose index utilized was CTDIvol and DLP. The 75th percentile of DLP distribution was calculated for comparison purposes. For Toshiba CT scanner the 75th percentile of CTDIvol values in head, chest, abdomen and chest /abdomen examinations were 54.7 mGy, 3.8 mGy, 7 mGy and 10.9 mGy, whilst the DLP values were 959 mGy*cm, 150.9 mGy*cm, 314.5 mGy*cm and 612.2 mGy*cm, respectively. For GE scanner the corresponding CTDIvol values were 110.4/58.6 mGy (post fossa/cerebrum), 11.9 mGy, 14.7 mGy and 13 mGy, whilst the DLP values were 447.7/713.3 mGy*cm (post fossa/cerebrum), 416.7 mGy*cm, 636.2 mGy*cm and 758.1 mGy*cm, respectively.
In addition, the relation of body mass index (BMI) with radiation dose was investigated, and showed a linear-like analogy between the two parameters in all body examinations. In head examination the dose values tend to create a horizontal form. A further categorization of the patients can be possible.
Finally, the 75th percentile of CTDIvol and DLP values of each examination were compared with the national and international DRLs. The corresponding values from Toshiba scanner were lower than national and international recommended DRLs. For GE scanner these values were comparable with the corresponding from other countries in all examinations. |
author2 |
Παναγιωτάκης, Γεώργιος |
author_facet |
Παναγιωτάκης, Γεώργιος Μόκα, Άλκηστη |
format |
Thesis |
author |
Μόκα, Άλκηστη |
author_sort |
Μόκα, Άλκηστη |
title |
Institutional patient dose levels in multislice computed tomography examinations |
title_short |
Institutional patient dose levels in multislice computed tomography examinations |
title_full |
Institutional patient dose levels in multislice computed tomography examinations |
title_fullStr |
Institutional patient dose levels in multislice computed tomography examinations |
title_full_unstemmed |
Institutional patient dose levels in multislice computed tomography examinations |
title_sort |
institutional patient dose levels in multislice computed tomography examinations |
publishDate |
2017 |
url |
http://hdl.handle.net/10889/10609 |
work_keys_str_mv |
AT mokaalkēstē institutionalpatientdoselevelsinmultislicecomputedtomographyexaminations AT mokaalkēstē dosēasthenōnseexetaseispolytomikēsypologistikēstomographias |
_version_ |
1771297148646719488 |
spelling |
nemertes-10889-106092022-09-05T04:59:25Z Institutional patient dose levels in multislice computed tomography examinations Δόση ασθενών σε εξετάσεις πολυτομικής υπολογιστικής τομογραφίας Μόκα, Άλκηστη Παναγιωτάκης, Γεώργιος Πέτσας, Θεόδωρος Καλογεροπούλου, Χριστίνα Μoka, Alkisti Computed tomography Institutional doses Υπολογιστική τομογραφία Δόση ασθενών 616.075 722 Computed tomography (CT) is a major source of radiation patient dose from medical exposure. During the last years CT examinations have increased a lot, so there is need for optimization of the patient dose. In this study the institutional doses for CT examinations for head, chest, abdomen and chest/abdomen, in the University Hospital of Patras are presented. The systems that have been used were Toshiba Aquilion Prime (80 slices) and General Electric Lightspeed 16 (16 slices). Totally four hundred patients participated in this study, fifty of each examination and system. Τhe patient characteristics (age, sex, body mass index (BMI)) were recorded. To calculate the patient dose the dose index utilized was CTDIvol and DLP. The 75th percentile of DLP distribution was calculated for comparison purposes. For Toshiba CT scanner the 75th percentile of CTDIvol values in head, chest, abdomen and chest /abdomen examinations were 54.7 mGy, 3.8 mGy, 7 mGy and 10.9 mGy, whilst the DLP values were 959 mGy*cm, 150.9 mGy*cm, 314.5 mGy*cm and 612.2 mGy*cm, respectively. For GE scanner the corresponding CTDIvol values were 110.4/58.6 mGy (post fossa/cerebrum), 11.9 mGy, 14.7 mGy and 13 mGy, whilst the DLP values were 447.7/713.3 mGy*cm (post fossa/cerebrum), 416.7 mGy*cm, 636.2 mGy*cm and 758.1 mGy*cm, respectively. In addition, the relation of body mass index (BMI) with radiation dose was investigated, and showed a linear-like analogy between the two parameters in all body examinations. In head examination the dose values tend to create a horizontal form. A further categorization of the patients can be possible. Finally, the 75th percentile of CTDIvol and DLP values of each examination were compared with the national and international DRLs. The corresponding values from Toshiba scanner were lower than national and international recommended DRLs. For GE scanner these values were comparable with the corresponding from other countries in all examinations. Η υπολογιστική τομογραφία είναι ένα ευρέως χρησιμοποιούμενο εργαλείο της διαγνωστικής ιατρικής που επιβαρύνει όμως με υψηλή δόση ακτινοβολίας τους ασθενείς. Τα τελευταία χρόνια έχει αυξηθεί σημαντικά ο αριθμός των εξετάσεων αξονικής τομογραφίας έτσι κρίνεται αναγκαίος ο περιορισμός των δόσεων, όσο είναι εφικτό. Σε αυτή τη μελέτη εξετάστηκαν οι δόσεις των ασθενών σε δύο διαφορετικούς αξονικούς τομογράφους. Ο αξονικός τομογράφος Toshiba Aquilion Prime (80 τομές) και ο General Electric Lightspeed 16 (16 τομές). Χρησιμοποιήθηκαν τα πρωτόκολλα λήψεων για εγκέφαλο, θώρακα, θωρακα & άνω / κάτω κοιλιά, άνω-κάτω κοιλιά. Στη μελέτη που έγινε μετρήθηκαν ο ογκομετρικός δείκτης CTDIvol και το γινόμενο δόσης-μήκους DLP . Επίσης έγινε η καταγραφή του ύψους, βάρους, φύλου και της ηλικίας του κάθε εξεταζόμενου. Για τον υπολογισμό της δόσης και τη σύγκριση μεταξύ τους αλλά και με άλλες μελέτες ορίστηκε ως τιμή αυτή που αντιστοιχεί στα τρία τέταρτα των κατανομών των μετρήσεων. Τα αποτελέσματα έδειξαν ότι τα τρία τέταρτα των κατανομών της τιμής του CTDIvol στις εξετάσεις κεφαλής θώρακα, κοιλίας (πλήρους) και θώρακος & άνω/κάτω κοιλίας στον αξονικό τομογράφο 80 τομών ήταν: 54.7 mGy, 3.8 mGy, 7 mGy και 10.9 mGy, ενώ οι αντίστοιχες τιμές DLP ήταν 959 mGy*cm, 150.9 mGy*cm, 314.5 mGy*cm και 612.2 mGy*cm. Για τον αξονικό τομογράφο 16 τομών οι αντίστοιχες τιμές του CTDIvol ήταν: 110.4/58.6 mGy (οπίσθιος κρανιακός βόθρος/υπόλοιπος εγκέφαλος), 11.9 mGy, 14.7 mGy and 13 mGy, ενώ οι τιμές του DLP ήταν 447.7/713.3 mGy*cm (οπίσθιος κρανιακός βόθρος/υπόλοιπος εγκέφαλος), 416.7 mGy*cm, 636.2 mGy*cm και 758.1 mGy*cm, αντίστοιχα. Eπίσης στην εργασία αυτή έγινε συσχέτιση των τιμών του CTDIvol και του DLP με τον δείκτη μάζας σώματος (BMI). Από την ανάλυση το αποτέλεσμα ήταν ότι υπήρξε γραμμική σχέση των τιμών αυτών ως προς τον ΔΜΣ για τις εξετάσεις σώματος. Όσον αφορά τις εξετάσεις εγκεφάλου η δόση παρουσίαζε σταθερές τιμές στο μεγαλύτερο μέρος του δείγματος. Σε κάποιες περιπτώσεις υπήρξε απόκλιση κάποιων τιμών από το συνηθισμένο μοτίβο, συνήθως σε ελάχιστες και μέγιστες τιμές του BMI. Τέλος, έγινε σύγκριση των υπολογισμένων τιμών με τα εθνικά και διεθνή διαγνωστικά επίπεδα αναφοράς. Οι τιμές των CTDIvol και DLP για τον αξονικό τομογράφο 80 τομών ήταν χαμηλότερες από τις συνιστώμενες αντίστοιχες τιμές των εθνικών και διεθνών Διαγνωστικών Επιπέδων Αναφοράς (ΔΕΑ) για όλες τις εξετάσεις. Συγκεκριμένα, για τις εξετάσει θώρακα οι τιμές ήταν εξαιρετικά χαμηλές, γεγονός που οφείλεται στην εξέλιξη της τεχνολογίας του συστήματος. Οι αντίστοιχες τιμές για τον αξονικό τομογράφο 16 τομών ήταν συγκρίσιμες με τα εθνικά ΔΕΑ καθώς και με τα προτεινόμενα ΔΕΑ των άλλων χωρών. 2017-08-25T06:27:51Z 2017-08-25T06:27:51Z 2017-06-19 Thesis http://hdl.handle.net/10889/10609 en 0 application/pdf |