Evaluation of the exposure index as a quality indicator in radiographic practice

A research, from June 2021 to June 2022, was conducted with 498 adult patients, who underwent some of the most typical diagnostic X–ray examinations (chest, abdomen and extremities). The data collection took place at Patra’s University General Hospital, which is located in Rio of Greece. For each pa...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριος συγγραφέας: Παππά, Αικατερίνη
Άλλοι συγγραφείς: Pappa, Aikaterini
Γλώσσα:English
Έκδοση: 2022
Θέματα:
Διαθέσιμο Online:https://hdl.handle.net/10889/23796
id nemertes-10889-23796
record_format dspace
institution UPatras
collection Nemertes
language English
topic Exposure index
Radiography
Δείκτης έκθεσης
Ακτινογραφία
spellingShingle Exposure index
Radiography
Δείκτης έκθεσης
Ακτινογραφία
Παππά, Αικατερίνη
Evaluation of the exposure index as a quality indicator in radiographic practice
description A research, from June 2021 to June 2022, was conducted with 498 adult patients, who underwent some of the most typical diagnostic X–ray examinations (chest, abdomen and extremities). The data collection took place at Patra’s University General Hospital, which is located in Rio of Greece. For each patient’s projection, data were recorded from the radiography system, such as such as exposure parameters (kVp, mA, ms), SID, field size, dosimetric parameters (DAP) and EI. The digital radiography systems brought into service were the Philips DigitalDiagnost (Philips Medical Systems, Netherlands, BV) and the AGFA DX-D 600 (Agfa HealthCare’s MUSICA). The radiography systems used for this study were under a systematic Quality Assurance (QA) and Quality Control (QC) (QA/QC) program by the Medical Physics Department of the hospital. Descriptive statistics were performed on the data. The Spearman’s rank correlation test was used for testing the correlation between the parameters for all DigitalDiagnost’s and AGFA’S projections. Where it was found, also with the help of scatter plots, that the EI is statistically dependent on the tube current and the exposure time. In addition, the Kruskal-Wallis H test was used to compare the medians of the EI values for more than two independent groups of kVp, SID, Field size and Image view. The results showed that the majority of the EI values from both systems fall within the same range, specifically (100 – 500) and that the median ΕΙ values don’t differ significantly for these parameters. Although, the DigitalDiagnost demonstrates a significantly larger range for the EI (100-2000) comparing to the AGFA system. Regarding the relationship of the EI and DAP, the trend line of the DigitalDiagnost system’s data shows that the EI remains relatively constant, as DAP increases, and equal to 400. The median value of the EI of all the DigitalDiagnost’s projections was also found equal to 400, from the Kruskall wallis H test. While, the trend line of the AGFA system’s data shows that EI slightly increases, as DAP increases too. While the median value of the EI of all the AGFA’s projections was found equal to 249, from the Kruskall wallis H test. In conclusion, the results of both systems don’t vary significantly.
author2 Pappa, Aikaterini
author_facet Pappa, Aikaterini
Παππά, Αικατερίνη
author Παππά, Αικατερίνη
author_sort Παππά, Αικατερίνη
title Evaluation of the exposure index as a quality indicator in radiographic practice
title_short Evaluation of the exposure index as a quality indicator in radiographic practice
title_full Evaluation of the exposure index as a quality indicator in radiographic practice
title_fullStr Evaluation of the exposure index as a quality indicator in radiographic practice
title_full_unstemmed Evaluation of the exposure index as a quality indicator in radiographic practice
title_sort evaluation of the exposure index as a quality indicator in radiographic practice
publishDate 2022
url https://hdl.handle.net/10889/23796
work_keys_str_mv AT pappaaikaterinē evaluationoftheexposureindexasaqualityindicatorinradiographicpractice
AT pappaaikaterinē axiologēsētoudeiktēekthesēsōsdeiktēpoiotētasstēnaktinographia
_version_ 1771297345115258880
spelling nemertes-10889-237962022-11-10T04:38:24Z Evaluation of the exposure index as a quality indicator in radiographic practice Αξιολόγηση του δείκτη έκθεσης ως δείκτη ποιότητας στην ακτινογραφία Παππά, Αικατερίνη Pappa, Aikaterini Exposure index Radiography Δείκτης έκθεσης Ακτινογραφία A research, from June 2021 to June 2022, was conducted with 498 adult patients, who underwent some of the most typical diagnostic X–ray examinations (chest, abdomen and extremities). The data collection took place at Patra’s University General Hospital, which is located in Rio of Greece. For each patient’s projection, data were recorded from the radiography system, such as such as exposure parameters (kVp, mA, ms), SID, field size, dosimetric parameters (DAP) and EI. The digital radiography systems brought into service were the Philips DigitalDiagnost (Philips Medical Systems, Netherlands, BV) and the AGFA DX-D 600 (Agfa HealthCare’s MUSICA). The radiography systems used for this study were under a systematic Quality Assurance (QA) and Quality Control (QC) (QA/QC) program by the Medical Physics Department of the hospital. Descriptive statistics were performed on the data. The Spearman’s rank correlation test was used for testing the correlation between the parameters for all DigitalDiagnost’s and AGFA’S projections. Where it was found, also with the help of scatter plots, that the EI is statistically dependent on the tube current and the exposure time. In addition, the Kruskal-Wallis H test was used to compare the medians of the EI values for more than two independent groups of kVp, SID, Field size and Image view. The results showed that the majority of the EI values from both systems fall within the same range, specifically (100 – 500) and that the median ΕΙ values don’t differ significantly for these parameters. Although, the DigitalDiagnost demonstrates a significantly larger range for the EI (100-2000) comparing to the AGFA system. Regarding the relationship of the EI and DAP, the trend line of the DigitalDiagnost system’s data shows that the EI remains relatively constant, as DAP increases, and equal to 400. The median value of the EI of all the DigitalDiagnost’s projections was also found equal to 400, from the Kruskall wallis H test. While, the trend line of the AGFA system’s data shows that EI slightly increases, as DAP increases too. While the median value of the EI of all the AGFA’s projections was found equal to 249, from the Kruskall wallis H test. In conclusion, the results of both systems don’t vary significantly. Έρευνα διεξήχθη, από τον Ιούνιο του 2021 έως τον Ιούνιο του 2022, με 498 ενήλικες ασθενείς, οι οποίοι υποβλήθηκαν σε μερικές από τις πιο τυπικές εξετάσεις ακτίνων-Χ (θώρακα, κοιλίας, άκρα). Η συλλογή των δεδομένων πραγματοποιήθηκε στο Πανεπιστημιακό Γενικό Νοσοκομείο Πατρών που βρίσκεται στο Ρίο, στην Ελλάδα. Για την ακτινογραφία κάθε ασθενούς καταγράφηκαν δεδομένα από το σύστημα ακτινογραφίας, όπως οι παράμετροι έκθεσης (τάση, ρεύμα, χρόνος έκθεσης), η απόσταση πηγής-εικόνας (SID), το μέγεθος πεδίου, δοσιμετρικές παράμετροι (DAP) και ο δείκτης έκθεσης (EI). Τα συστήματα ψηφιακής ακτινογραφίας που τέθηκαν σε λειτουργία ήταν το Philips DigitalDiagnost (Philips Medical Systems, Ολλανδία, BV) και το AGFA DX-D 600 (Agfa HealthCare’s MUSICA). Τα συστήματα αυτά υποβλήθηκαν σε συστηματικό πρόγραμμα Διασφάλισης Ποιότητας (QA) και Ποιοτικού Ελέγχου (QA/QC) από το τμήμα Ιατρικής Φυσικής του νοσοκομείου. Περιγραφική στατιστική χρησιμοποιήθηκε για τα δεδομένα. Ο έλεγχος συσχέτισης Spearman χρησιμοποιήθηκε για τη διερεύνηση συσχέτισης μεταξύ των παραμέτρων όλων των ακτινογραφιών του DigitalDiagnost και του AGFA. Όπου βρέθηκε, κι από τη χρήση διαγραμμάτων διασποράς, ότι o ΕΙ έχει σημαντική στατιστική εξάρτηση με το ρεύμα και το χρόνο έκθεσης. Επιπλέον, ο έλεγχος Kruskal-Wallis χρησιμοποιήθηκε για τη σύγκριση των διαμέσων των τιμών EI που αντιστοιχούν σε περισσότερες από δύο ανεξάρτητες ομάδες τάσης, απόστασης πηγής-εικόνας, μέγεθος πεδίου και προβολής. Τα αποτελέσματα έδειξαν ότι η πλειοψηφία των τιμών EI κι από τα δύο συστήματα εμπίπτει στο ίδιο εύρος, συγκεκριμένα (100 – 500) και ότι οι διάμεσοι του ΕΙ δεν διαφέρουν σημαντικά για αυτές τις παραμέτρους. Ωστόσο, το DigitalDiagnost επιδεικνύει ένα σημαντικά μεγαλύτερο εύρος για τον EI (100-2000) σε σύγκριση με το σύστημα AGFA. Όσον αφορά τη σχέση του EI και του DAP, η γραμμή τάσης των δεδομένων του συστήματος DigitalDiagnost δείχνει ότι ο EI παραμένει σχετικά σταθερός, καθώς το DAP αυξάνεται, και είναι ίσος με 400. Η διάμεσος του EI όλων των προβολών του DigitalDiagnost βρέθηκε επίσης ίση με 400, από τον έλεγχο Kruskall wallis. Ενώ, η γραμμή τάσης των δεδομένων του συστήματος AGFA δείχνει ότι ο ΕΙ αυξάνεται ελαφρά, καθώς το DAP αυξάνεται επίσης. Ενώ η διάμεσος του ΕΙ όλων των προβολών της AGFA βρέθηκε ίση με 249, από τη δοκιμή Kruskall wallis. Συμπερασματικά, τα αποτελέσματα και των δύο συστημάτων δεν διαφέρουν σημαντικά. 2022-11-09T06:56:05Z 2022-11-09T06:56:05Z 2022-07-19 https://hdl.handle.net/10889/23796 en Attribution-NonCommercial-NoDerivs 3.0 United States http://creativecommons.org/licenses/by-nc-nd/3.0/us/ application/pdf