Patient dose estimation in CT guided biopsy procedures

This study reports the establishment of Typical Diagnostic Reference Levels (DRLs) values and the estimation of patients' doses during computed tomography (CT)- guided biopsy procedures. To determine the doses received by patients, effective dose (ED), entrance skin dose (ESD), and size-speci...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριος συγγραφέας: Σιώμου, Ευαγγελία
Άλλοι συγγραφείς: Siomou, Evangelia
Γλώσσα:English
Έκδοση: 2023
Θέματα:
Διαθέσιμο Online:https://hdl.handle.net/10889/25220
id nemertes-10889-25220
record_format dspace
institution UPatras
collection Nemertes
language English
topic Typical Diagnostic Reference Levels (DRLs)
Computed tomography (CT)
Διαγνωστικά επίπεδα αναφοράς (ΔΕΑ)
Δόσεις ακτινοβολίας
spellingShingle Typical Diagnostic Reference Levels (DRLs)
Computed tomography (CT)
Διαγνωστικά επίπεδα αναφοράς (ΔΕΑ)
Δόσεις ακτινοβολίας
Σιώμου, Ευαγγελία
Patient dose estimation in CT guided biopsy procedures
description This study reports the establishment of Typical Diagnostic Reference Levels (DRLs) values and the estimation of patients' doses during computed tomography (CT)- guided biopsy procedures. To determine the doses received by patients, effective dose (ED), entrance skin dose (ESD), and size-specific dose estimate (SSDE) were calculated using conversion factors derived from the literature. Research’s sample was taken from “Attikon” University Hospital. Five categories of CT-guided percutaneous needle biopsies were analyzed, including iliac bone biopsies (n=48), liver biopsies (n=57), lung biopsies (n=57), mediastinum biopsies (n=33), and para-aortic tissue biopsies (n=31). A total of 226 CT-guided biopsies performed from January 2017 to October 2022 by a single interventional radiologist were reviewed, and all technical and dosimetric parameters were retrospectively collected for analysis using DICOM data. Typical values of DRLs were calculated as the median values of the distributions. DRL values were proposed for the CTDIvol for the five categories of CT-guided biopsy procedures. DRLs in terms of CTDIvol were 9.7 mGy for Iliac bone, 8.9 mGy for liver, 8.8 mGy for lung, 7.9 mGy for mediastinal mass and 9 mGy for para-aortic lymph nodes biopsy procedures for helical mode acquisitions. For biopsy scans, DRL values were found to be 7.3 mGy, 7.7 mGy, 5.6 mGy, 5.6 mGy and 7.4 mGy respevtively. Typical DLRs were established as per the latest International Commission on Radiological Protection report 135 definition for five categories of CT-guided biopsy procedures without use of fluoroscopy. Helical scans across the entire anatomical region greatly affect radiation dose compared to biopsy acquisitions.
author2 Siomou, Evangelia
author_facet Siomou, Evangelia
Σιώμου, Ευαγγελία
author Σιώμου, Ευαγγελία
author_sort Σιώμου, Ευαγγελία
title Patient dose estimation in CT guided biopsy procedures
title_short Patient dose estimation in CT guided biopsy procedures
title_full Patient dose estimation in CT guided biopsy procedures
title_fullStr Patient dose estimation in CT guided biopsy procedures
title_full_unstemmed Patient dose estimation in CT guided biopsy procedures
title_sort patient dose estimation in ct guided biopsy procedures
publishDate 2023
url https://hdl.handle.net/10889/25220
work_keys_str_mv AT siōmoueuangelia patientdoseestimationinctguidedbiopsyprocedures
AT siōmoueuangelia ektimēsēdoseōnasthenōnsebiopsiesypotēnkathodēgēsēaxonikoutomographou
_version_ 1771297245687185408
spelling nemertes-10889-252202023-06-29T03:56:48Z Patient dose estimation in CT guided biopsy procedures Εκτίμηση δόσεων ασθενών σε βιοψίες υπό την καθοδήγηση αξονικού τομογράφου Σιώμου, Ευαγγελία Siomou, Evangelia Typical Diagnostic Reference Levels (DRLs) Computed tomography (CT) Διαγνωστικά επίπεδα αναφοράς (ΔΕΑ) Δόσεις ακτινοβολίας This study reports the establishment of Typical Diagnostic Reference Levels (DRLs) values and the estimation of patients' doses during computed tomography (CT)- guided biopsy procedures. To determine the doses received by patients, effective dose (ED), entrance skin dose (ESD), and size-specific dose estimate (SSDE) were calculated using conversion factors derived from the literature. Research’s sample was taken from “Attikon” University Hospital. Five categories of CT-guided percutaneous needle biopsies were analyzed, including iliac bone biopsies (n=48), liver biopsies (n=57), lung biopsies (n=57), mediastinum biopsies (n=33), and para-aortic tissue biopsies (n=31). A total of 226 CT-guided biopsies performed from January 2017 to October 2022 by a single interventional radiologist were reviewed, and all technical and dosimetric parameters were retrospectively collected for analysis using DICOM data. Typical values of DRLs were calculated as the median values of the distributions. DRL values were proposed for the CTDIvol for the five categories of CT-guided biopsy procedures. DRLs in terms of CTDIvol were 9.7 mGy for Iliac bone, 8.9 mGy for liver, 8.8 mGy for lung, 7.9 mGy for mediastinal mass and 9 mGy for para-aortic lymph nodes biopsy procedures for helical mode acquisitions. For biopsy scans, DRL values were found to be 7.3 mGy, 7.7 mGy, 5.6 mGy, 5.6 mGy and 7.4 mGy respevtively. Typical DLRs were established as per the latest International Commission on Radiological Protection report 135 definition for five categories of CT-guided biopsy procedures without use of fluoroscopy. Helical scans across the entire anatomical region greatly affect radiation dose compared to biopsy acquisitions. Σκοπός της παρούσας μελέτης είναι η καθιέρωση των Διαγνωστικών Επιπέδων Αναφοράς (ΔΕΑ) και ο υπολογισμός των δόσεων ακτινοβολίας που λαμβάνουν οι ασθενείς κατά τη διάρκεια των διαδικασιών βιοψίας υπό την καθοδήγηση αξονικού τομογράφου. Για τον υπολογισμό των δόσεων που λαμβάνουν οι ασθενείς, μετρήθηκαν η ενεργός δόση ED, η δόση εισόδου ESD και ο δείκτης δόσης SSDE μέσω συντελεστών μετατροπής που προέρχονται από τη βιβλιογραφία. Το δείγμα αυτής της έρευνας πάρθηκε από το Πανεπιστημιακό Νοσοκομείο «ΑΤΤΙΚΟΝ». Πέντε κατηγορίες βιοψιών καθοδηγούμενες από αξονικό τομογράφο με την χρήση λεπτής βελόνης διερευνήθηκαν. Αυτές περιλαμβάνουν βιοψίες λαγονίου οστού (48 ασθενείς), βιοψίες ήπατος (57 ασθενείς), βιοψίες πνεύμονα (57 ασθενείς), βιοψίες μεσοθωρακικής μάζας (33 ασθενείς) και βιοψίες παρα-αορτικών λεμφαδένων (31 ασθενείς). Συνολικά, εξετάστηκαν 226 βιοψίες, όπου οι ασθενείς υποβλήθηκαν σε αυτές από τον Ιανουάριο του 2017 έως τον Οκτώβριο του 2022 και οι οποίες πραγματοποιήθηκαν από έναν επεμβατικό ακτινολόγο. Όλες οι τεχνικές και δοσιμετρικές παράμετροι συλλέχθηκαν για ανάλυση χρησιμοποιώντας τα δεδομένα DICOM. Οι τυπικές τιμές ΔΕΑ υπολογίστηκαν ως οι μέσες τιμές των κατανομών. Οι τυπικές τιμές ΔΕΑ προτάθηκαν για τις πέντε παραπάνω κατηγορίες βιοψιών υπό την καθοδήγηση αξονικού τομογράφου. Οι τιμές των ΔΕΑ υπό το πρίσμα του CTDIvol υπολογίστηκαν ως 9,7 mGy για τις βιοψίες λαγονίου οστού, 8,9 mGy για τις βιοψίες ήπατος, 8,8 mGy για τις βιοψίες πνεύμονα, 7,9 mGy για τις βιοψίες μεσοθωρακικής μάζας και τέλος 9 mGy για τις βιοψίες παρα-αορτικών λεμφαδένων για τις ελικοειδείς σαρώσεις. Για τις σαρώσεις βιοψίας, οι τιμές ΔΕΑ βρέθηκαν να είναι 7,3 mGy, 7,7 mGy, 5,6 mGy, 5,6 mGy και 7,4 mGy αντίστοιχα. Οι τυπικές τιμές ΔΕΑ καθορίστηκαν σύμφωνα με το ICRP 135 για τις πέντε κατηγορίες βιοψιών υπό την καθοδήγηση αξονικού τομογράφου, χωρίς την χρήση ακτινοσκόπησης. Οι ελικοειδείς σαρώσεις κατά μήκος ολόκληρης της ανατομικής περιοχής επηρεάζουν σημαντικά την δόση ακτινοβιλίας σε σύγκριση με εκείνες των βιοψιών. 2023-06-28T06:08:19Z 2023-06-28T06:08:19Z 2023-05-18 https://hdl.handle.net/10889/25220 en application/pdf