Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom

In the current study, we present measurements of peripheral dose that is absorbed by specific radio-sensitive organs outside the radiation field for five clinical cases, and compare them with the corresponding values that are given by ISIS 3D Treatment Planning System, as well as with the values giv...

Full description

Bibliographic Details
Main Author: Παπαθανάσης, Χαράλαμπος
Other Authors: Παναγιωτάκης, Γιώργος
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://nemertes.lis.upatras.gr/jspui/handle/10889/2545
id nemertes-10889-2545
record_format dspace
spelling nemertes-10889-25452022-09-05T05:38:43Z Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom Μετρήσεις της περιφερειακής ζώνης σε πέντε κλινικές περιπτώσεις ακτινοθεραπείας με ανιχνευτές Mosfet σε ανθρωπόμορφο ομοίωμα Παπαθανάσης, Χαράλαμπος Παναγιωτάκης, Γιώργος Παναγιωτάκης, Γιώργος Καρδαμάκης, Δημήτρης Κωσταρίδου, Ελένη Papathanasis, Charalampos MOSFET dosimeters Peripheral dose Ανιχνευτές MOSFET Περιφερειακή δόση 615.842 4 In the current study, we present measurements of peripheral dose that is absorbed by specific radio-sensitive organs outside the radiation field for five clinical cases, and compare them with the corresponding values that are given by ISIS 3D Treatment Planning System, as well as with the values given by a software that can calculate peripheral doses called ‘Peridose’. The measurements were made with MOSFET dosimeters in anthropomorphic phantom. Στην παρούσα εργασία, παρουσιάζουμε μετρήσεις της περιφερειακής δόσης που απορροφάται από συγκεκριμένα ακτινευαίσθητα όργανα εκτός του πεδίου ακτινοβόλησης για πέντε κλινικές περιπτώσεις, και τις συγκρίνουμε με τις αντίστοιχες τιμές που δίνονται από το ISIS 3D Treatment Planning System καθώς και από τις τιμές που δίνει ένα πρόγραμμα το οποίο μπορεί να υπολογίσει περιφερειακές δόσεις που λέγεται ‘Peridose’. Οι μετρήσεις έγιναν με δοσίμετρα MOSFET σε ανθρωπόμορφο ομοίωμα. 2010-01-19T09:48:15Z 2010-01-19T09:48:15Z 2009-09-30 2010-01-19T09:48:15Z Thesis http://nemertes.lis.upatras.gr/jspui/handle/10889/2545 en Η ΒΥΠ διαθέτει αντίτυπο της διατριβής σε έντυπη μορφή στο βιβλιοστάσιο διδακτορικών διατριβών που βρίσκεται στο ισόγειο του κτιρίου της. 0 application/pdf
institution UPatras
collection Nemertes
language English
topic MOSFET dosimeters
Peripheral dose
Ανιχνευτές MOSFET
Περιφερειακή δόση
615.842 4
spellingShingle MOSFET dosimeters
Peripheral dose
Ανιχνευτές MOSFET
Περιφερειακή δόση
615.842 4
Παπαθανάσης, Χαράλαμπος
Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom
description In the current study, we present measurements of peripheral dose that is absorbed by specific radio-sensitive organs outside the radiation field for five clinical cases, and compare them with the corresponding values that are given by ISIS 3D Treatment Planning System, as well as with the values given by a software that can calculate peripheral doses called ‘Peridose’. The measurements were made with MOSFET dosimeters in anthropomorphic phantom.
author2 Παναγιωτάκης, Γιώργος
author_facet Παναγιωτάκης, Γιώργος
Παπαθανάσης, Χαράλαμπος
format Thesis
author Παπαθανάσης, Χαράλαμπος
author_sort Παπαθανάσης, Χαράλαμπος
title Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom
title_short Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom
title_full Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom
title_fullStr Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom
title_full_unstemmed Measurements of periferal dose in five clinical radiotherapy cases with Mosfet detectors in anthropomorphic phantom
title_sort measurements of periferal dose in five clinical radiotherapy cases with mosfet detectors in anthropomorphic phantom
publishDate 2010
url http://nemertes.lis.upatras.gr/jspui/handle/10889/2545
work_keys_str_mv AT papathanasēscharalampos measurementsofperiferaldoseinfiveclinicalradiotherapycaseswithmosfetdetectorsinanthropomorphicphantom
AT papathanasēscharalampos metrēseistēsperiphereiakēszōnēssepenteklinikesperiptōseisaktinotherapeiasmeanichneutesmosfetseanthrōpomorphoomoiōma
_version_ 1771297153549860864