Optimization of internal target volumes in radiotherapy
The purpose of this study was to investigate whether it is possible to create the ITV using a reduced set of 4DCT phases. Methods: Ten lung cancer patients were identified who had received 4DCT imaging as part of their treatment simulation, and who had a noticeable tumor motion. For each patient, a...
Κύριος συγγραφέας: | |
---|---|
Άλλοι συγγραφείς: | |
Μορφή: | Thesis |
Γλώσσα: | English |
Έκδοση: |
2010
|
Θέματα: | |
Διαθέσιμο Online: | http://nemertes.lis.upatras.gr/jspui/handle/10889/3684 |
id |
nemertes-10889-3684 |
---|---|
record_format |
dspace |
institution |
UPatras |
collection |
Nemertes |
language |
English |
topic |
Target volume Radiotherapy Optimization Στόχος όγκου Ακτινοθεραπεία Βελτιστοποίηση 616.994 064 2 |
spellingShingle |
Target volume Radiotherapy Optimization Στόχος όγκου Ακτινοθεραπεία Βελτιστοποίηση 616.994 064 2 Γιακουμάκης, Νικόλαος Optimization of internal target volumes in radiotherapy |
description |
The purpose of this study was to investigate whether it is possible to create the ITV using a reduced set of 4DCT phases.
Methods: Ten lung cancer patients were identified who had received 4DCT imaging as part of their treatment simulation, and who had a noticeable tumor motion. For each patient, a GTV was drawn on the exhale phase, based on the original physician-drawn ITV (our clinical practice is for the physician to directly draw the ITV based using the 4DCT images). This GTV was then propagated to the other phases of the 4DCT using a commercial image registration package (MIMVista, Cleveland OH). 4 different ITVs were created using N phases closest to exhale (N=1-10). For each ITV contour a RapidArc plan was created on the exhale phase CT, normalized so that the 95% isodose line covered at least 95% of the ITV. Each plan was applied to each CT phase (1-10), and the doses deformably mapped to the exhale phase. The effect of the motion was quantified in terms of the dose to the 95% of the target on the exhale phase (D95). The change in these parameters as N was reduced from 10 was calculated. Also, the difference in the 3D calculations of the original plans and the 4D calculations was noted as a function of N.
Results: Differences in 3D and 4D dose calculations varied from 3% to 14% with an average of 7% for ITV_10/10. For 9 out 10 of ten patients we can have less than 5% reduction in the D95 by using ITV_8/10. For 3 out of ten patients we can have less than 5% reduction in the D95 by using ITV_7/10 and for 1 out of 10 patients we can patients we can have less than 5% reduction in the D95 by using ITV_6/10.
Conclusions: No rule for reducing ITV works for all patients. Some reduction (8/10 phases) is possible for most of the patients but not all and also the volume reduction is small. Therefore what we are currently doing is reasonable. 4D dose calculations give different DVHs to 3D also shown by other groups. Reduction in ITV volume is possible for some patients (e.g. patient 2 17% reduction), but 4D dose calculation is necessary. |
author2 |
Παναγιωτάκης, Γεώργιος |
author_facet |
Παναγιωτάκης, Γεώργιος Γιακουμάκης, Νικόλαος |
format |
Thesis |
author |
Γιακουμάκης, Νικόλαος |
author_sort |
Γιακουμάκης, Νικόλαος |
title |
Optimization of internal target volumes in radiotherapy |
title_short |
Optimization of internal target volumes in radiotherapy |
title_full |
Optimization of internal target volumes in radiotherapy |
title_fullStr |
Optimization of internal target volumes in radiotherapy |
title_full_unstemmed |
Optimization of internal target volumes in radiotherapy |
title_sort |
optimization of internal target volumes in radiotherapy |
publishDate |
2010 |
url |
http://nemertes.lis.upatras.gr/jspui/handle/10889/3684 |
work_keys_str_mv |
AT giakoumakēsnikolaos optimizationofinternaltargetvolumesinradiotherapy AT giakoumakēsnikolaos beltistopoiēsētōnesōterikōnonkōnstochōnstēnaktinotherapeia |
_version_ |
1771297255354007552 |
spelling |
nemertes-10889-36842022-09-05T13:59:57Z Optimization of internal target volumes in radiotherapy Βελτιστοποίηση των εσωτερικών όγκων στόχων στην ακτινοθεραπεία Γιακουμάκης, Νικόλαος Παναγιωτάκης, Γεώργιος Νικηφορίδης, Γεώργιος Καρδαμάκης, Δημήτριος Παναγιωτάκης, Γεώργιος Giakoumakis, Nikolaos Target volume Radiotherapy Optimization Στόχος όγκου Ακτινοθεραπεία Βελτιστοποίηση 616.994 064 2 The purpose of this study was to investigate whether it is possible to create the ITV using a reduced set of 4DCT phases. Methods: Ten lung cancer patients were identified who had received 4DCT imaging as part of their treatment simulation, and who had a noticeable tumor motion. For each patient, a GTV was drawn on the exhale phase, based on the original physician-drawn ITV (our clinical practice is for the physician to directly draw the ITV based using the 4DCT images). This GTV was then propagated to the other phases of the 4DCT using a commercial image registration package (MIMVista, Cleveland OH). 4 different ITVs were created using N phases closest to exhale (N=1-10). For each ITV contour a RapidArc plan was created on the exhale phase CT, normalized so that the 95% isodose line covered at least 95% of the ITV. Each plan was applied to each CT phase (1-10), and the doses deformably mapped to the exhale phase. The effect of the motion was quantified in terms of the dose to the 95% of the target on the exhale phase (D95). The change in these parameters as N was reduced from 10 was calculated. Also, the difference in the 3D calculations of the original plans and the 4D calculations was noted as a function of N. Results: Differences in 3D and 4D dose calculations varied from 3% to 14% with an average of 7% for ITV_10/10. For 9 out 10 of ten patients we can have less than 5% reduction in the D95 by using ITV_8/10. For 3 out of ten patients we can have less than 5% reduction in the D95 by using ITV_7/10 and for 1 out of 10 patients we can patients we can have less than 5% reduction in the D95 by using ITV_6/10. Conclusions: No rule for reducing ITV works for all patients. Some reduction (8/10 phases) is possible for most of the patients but not all and also the volume reduction is small. Therefore what we are currently doing is reasonable. 4D dose calculations give different DVHs to 3D also shown by other groups. Reduction in ITV volume is possible for some patients (e.g. patient 2 17% reduction), but 4D dose calculation is necessary. Ο σκοπός αυτής της εργασίας είναι να ερευνήσουμε εάν είναι εφικτή η δημιουργία ενός ITV το οποίο θα αποτελείται από μειωμένες φάσεις του 4DCT. Μέθοδοι: Για την εργασία χρησιμοποιήθηκαν δέκα ασθενείς με διαγνωσμένο καρκίνο του πνεύμονα οι οποίοι είχαν λάβει 4DCT σαν μέρος της εξομοίωσης τής θεραπείας τους. Για κάθε ασθενή ένα GTV σχεδιάστηκε στην φάση της εκπνοής του 4DCT. To συγκεκριμένο GTV τοποθετήθηκε ανάλογα και στις υπόλοιπες φάσεις του 4DCT χρησιμοποιώντας ειδικό λογισμικό με δυνατότητες ‘deformable registration’ (MIMVista, Cleveland OH). 4 διαφορετικά ITVs δημιουργήθηκαν χρησιμοποιώντας Ν φάσεις πλησιέστερα στην εκπνοή (Ν=1-10). Για κάθε ITV ενα πλάνο VMAT δημιουργήθηκε στην φάση της εκπνοής, και κανονικοποιήθηκε ώστε το 95% του στόχου να παίρνει τουλάχιστον 95% της δόσης. Κάθε πλάνο εφαρμόστηκε σε όλες τις υπόλοιπες φάσεις του 4DCT και η αθροιστική δόση που παίρνει το GTV από όλο τον αναπνευστικό κύκλο υπολογίστηκε στη φάση της εκπνοής. Το πόσο επηρεάζει η κίνηση υπολογίστηκε με όρους δόσης στο 95% του στόχου πάνω στην φάση της εκπνοής (D95). Επίσης η διαφορά μεταξύ των 3D και των 4D υπολογισμών δόσης υπολογίστηκε σαν συνάρτηση του Ν (Ν=1-10). Αποτελέσματα: Παρατηρήθηκαν διαφορές στους 3D και 4D υπολογισμούς δόσης από 3% έως 14% με μέσο όρο 7% για το ITV_10/10. Σε 9 από τους 10 μπορούμε να πετύχουμε μείωση μικρότερη του 5% στο D95 χρησιμοποιώντας το ITV_8/10. Σε 3 από τους 10 ασθενείς μπορούμε να πετύχουμε μείωση μικρότερη του 5% στο D95 χρησιμοποιώντας το ITV_7/10 και για 1 από τους 10 ασθενείς μπορούμε να πετύχουμε μείωση μικρότερη το 5% στο D95 χρησιμοποιώντας το ITV_6/10. Συμπεράσματα: Δεν υπάρχει γενικός κανόνας για την μείωση του ITV για όλους τους ασθενείς. Συνιστάται εξατομίκευση θεραπείας. Η μείωση των φάσεων σε 8 από 10 φαίνεται αποτελεσματική για τους περισσότερους αλλά όχι όλους τους ασθενείς. Η μείωση του όγκου που προκύπτει είναι σχετικά μικρή. Η τρέχουσα πρακτική στην κλινική εφαρμογή φαίνεται και λογική και αποτελεσματική. 2010-09-20T05:26:35Z 2010-09-20T05:26:35Z 2010 2010-09-20T05:26:35Z Thesis http://nemertes.lis.upatras.gr/jspui/handle/10889/3684 en Η ΒΚΠ διαθέτει αντίτυπο της διατριβής σε έντυπη μορφή στο βιβλιοστάσιο διδακτορικών διατριβών που βρίσκεται στο ισόγειο του κτιρίου της. 0 application/pdf |