Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality
Diagnostic radiology plays an important role in the assessment and treatment of neonates, mainly premature, requiring intensive care in the Special Baby Care Unit (SBCU), because they have highly mitotic state of their cells and thus they are more radiosensitive. It is often necessary to perform a l...
Κύριος συγγραφέας: | |
---|---|
Άλλοι συγγραφείς: | |
Μορφή: | Thesis |
Γλώσσα: | English |
Έκδοση: |
2013
|
Θέματα: | |
Διαθέσιμο Online: | http://hdl.handle.net/10889/6243 |
id |
nemertes-10889-6243 |
---|---|
record_format |
dspace |
institution |
UPatras |
collection |
Nemertes |
language |
English |
topic |
Neonatal radiography Computed radiography Screen film images Image quality Evaluation of dose Entrance surface dose Ακτινογραφίες νεογνών Ψηφιακες εικόνες Αναλογικές συμβατικές εικόνες Ποιότητα εικόνας Αξιολόγηση δόσης 618.920 1 |
spellingShingle |
Neonatal radiography Computed radiography Screen film images Image quality Evaluation of dose Entrance surface dose Ακτινογραφίες νεογνών Ψηφιακες εικόνες Αναλογικές συμβατικές εικόνες Ποιότητα εικόνας Αξιολόγηση δόσης 618.920 1 Τακτικού, Ελευθερία Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality |
description |
Diagnostic radiology plays an important role in the assessment and treatment of neonates, mainly premature, requiring intensive care in the Special Baby Care Unit (SBCU), because they have highly mitotic state of their cells and thus they are more radiosensitive. It is often necessary to perform a large number of X-ray examinations depending upon the infant's birth-weight, gestational age and respiratory problems. It is therefore important to ensure that radiation doses from radiographic examinations carried out in neo-natal units are kept to a minimum while maintaining the quality of radiographic images in a high level.
An optimization study on radiation dose and image quality in neonatal radiography is presented. Our sample consists of 135 neonatal radiographic examinations, which performed on 54 neonates. All examinations were performed using the same mobile unit and under manual exposure control. Neonates were categorized into four groups depending on birth-weight. ESD was estimated from the exposure parameters (kVp, mAs) and tube output and also with using of Dose-Area Product (DAP). For the evaluation of image quality, our sample consists of 195 images (75 screen film images, 60 CR images in printed form and 60 CR images in electronic form) were assessed by two observers and were based on the visibility of certain anatomical features using a five-grade scale. ESDoutput values increased with increasing weight and ranged from 16.8 μGy to 64.7 μGy, with a mean value of 36 μGy for all radiographs. Similarly, ESDDAP values ranged from 14.8 μGy to 48.5 μGy with a mean of 29 μGy. Analyzing, the mean ESD for CR images was found 34.8 μGy and for screen film images 36.9 μGy. ESD values for CR images have the same behavior as ESD values for SF images. However, the majority of the acquired values are lower than the proposed Dose Reference Levels by Commission of European Communities (CEC: 80 μGy) and National Radiological Protection Board (NRPB: 50 μGy). Image quality evaluation revealed the feasibility of achieving a diagnostically satisfactory image using both low and high tube voltage techniques, with the latter resulting in reduced ESDs.
The results suggest that the use of high tube voltage techniques could result in further reductions in neonatal dose, without image quality degradation, underlying the requirement for establishing standard examination protocols for neonatal radiography with respect to neonatal weight. |
author2 |
Παναγιωτάκης, Γεώργιος |
author_facet |
Παναγιωτάκης, Γεώργιος Τακτικού, Ελευθερία |
format |
Thesis |
author |
Τακτικού, Ελευθερία |
author_sort |
Τακτικού, Ελευθερία |
title |
Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality |
title_short |
Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality |
title_full |
Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality |
title_fullStr |
Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality |
title_full_unstemmed |
Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality |
title_sort |
radiographic imaging of neonates with digital and analog techniques : comparative evaluation of dose and image quality |
publishDate |
2013 |
url |
http://hdl.handle.net/10889/6243 |
work_keys_str_mv |
AT taktikoueleutheria radiographicimagingofneonateswithdigitalandanalogtechniquescomparativeevaluationofdoseandimagequality AT taktikoueleutheria aktinographikēapeikonisēneognōnmepsēphiakeskaianalogikestechnikessynkritikēaxiologēsēdosēskaipoiotētaseikonas |
_version_ |
1771297128690221056 |
spelling |
nemertes-10889-62432022-09-05T05:00:13Z Radiographic imaging of neonates with digital and analog techniques : Comparative evaluation of dose and image quality Ακτινογραφική απεικόνιση νεογνών με ψηφιακές και αναλογικές τεχνικές : Συγκριτική αξιολόγηση δόσης και ποιότητας εικόνας Τακτικού, Ελευθερία Παναγιωτάκης, Γεώργιος Παναγιωτάκης, Γεώργιος Καλογεροπούλου, Χριστίνα Καρατζά, Αγγελική Taktikou, Eleftheria Neonatal radiography Computed radiography Screen film images Image quality Evaluation of dose Entrance surface dose Ακτινογραφίες νεογνών Ψηφιακες εικόνες Αναλογικές συμβατικές εικόνες Ποιότητα εικόνας Αξιολόγηση δόσης 618.920 1 Diagnostic radiology plays an important role in the assessment and treatment of neonates, mainly premature, requiring intensive care in the Special Baby Care Unit (SBCU), because they have highly mitotic state of their cells and thus they are more radiosensitive. It is often necessary to perform a large number of X-ray examinations depending upon the infant's birth-weight, gestational age and respiratory problems. It is therefore important to ensure that radiation doses from radiographic examinations carried out in neo-natal units are kept to a minimum while maintaining the quality of radiographic images in a high level. An optimization study on radiation dose and image quality in neonatal radiography is presented. Our sample consists of 135 neonatal radiographic examinations, which performed on 54 neonates. All examinations were performed using the same mobile unit and under manual exposure control. Neonates were categorized into four groups depending on birth-weight. ESD was estimated from the exposure parameters (kVp, mAs) and tube output and also with using of Dose-Area Product (DAP). For the evaluation of image quality, our sample consists of 195 images (75 screen film images, 60 CR images in printed form and 60 CR images in electronic form) were assessed by two observers and were based on the visibility of certain anatomical features using a five-grade scale. ESDoutput values increased with increasing weight and ranged from 16.8 μGy to 64.7 μGy, with a mean value of 36 μGy for all radiographs. Similarly, ESDDAP values ranged from 14.8 μGy to 48.5 μGy with a mean of 29 μGy. Analyzing, the mean ESD for CR images was found 34.8 μGy and for screen film images 36.9 μGy. ESD values for CR images have the same behavior as ESD values for SF images. However, the majority of the acquired values are lower than the proposed Dose Reference Levels by Commission of European Communities (CEC: 80 μGy) and National Radiological Protection Board (NRPB: 50 μGy). Image quality evaluation revealed the feasibility of achieving a diagnostically satisfactory image using both low and high tube voltage techniques, with the latter resulting in reduced ESDs. The results suggest that the use of high tube voltage techniques could result in further reductions in neonatal dose, without image quality degradation, underlying the requirement for establishing standard examination protocols for neonatal radiography with respect to neonatal weight. Η Διαγνωστική ακτινολογία παίζει σημαντικό ρόλο στην αξιολόγηση και τη θεραπεία των νεογνών, κυρίως των πρόωρων, καθώς απαιτείται η εντατική φροντίδα τους στην Ειδική Μονάδα Φροντίδας Νεογνών, λόγω της μεγάλης μιτωτικής δραστηριότητας των κυττάρων τους και κατα συνέπεια της ακτινοευαισθησίας τους. Είναι συχνά απαραίτητο να πραγματοποιηθεί ένας μεγάλος αριθμός ακτινογραφικών εξετάσεων που εξαρτώνται από το βάρος γέννησης, την περίοδο κύησης και τα αναπνευστικά προβλήματα. Επομένως, είναι σημαντικό να εξασφαλιστεί ότι οι δόσεις ακτινοβολίας από ακτινογραφικές εξετάσεις που πραγματοποιούνται σε μονάδες νεογνών περιορίζονται στο ελάχιστο, ενώ η ποιότητα των ακτινογραφικών εικόνων διατηρείται σε υψηλά επίπεδα. Μια μελέτη για τη βελτιστοποίηση της δόσης της ακτινοβολίας και της ποιότητας της εικόνας σε ακτινογραφίες νεογνών παρουσιάζεται παρακάτω. Το δείγμα μας αποτελείται από 135 ακτινογραφικές εξετάσεις νεογνών, οι οποίες πραγματοποιήθηκαν σε 54 νεογνά. Όλες οι εξετάσεις πραγματοποιήθηκαν χρησιμοποιώντας την ίδια φορητή ακτινογραφική μονάδα και με χειροκίνητο έλεγχο έκθεσης. Τα νεογνά ταξινομήθηκαν σε τέσσερις ομάδες ανάλογα με το βάρος γέννησης. Η Επιφανειακή δόση (ESD) εκτιμήθηκε από τις παραμέτρους της έκθεσης (kVp, mΑs), αλλά και με τη χρήση του DAP. Για την αξιολόγηση της ποιότητας της εικόνας, το δείγμα αποτελούνταν από 195 εικόνες (75 συμβατικές, 60 ψηφιακές (CR) σε έντυπη μορφή και 60 ψηφιακές εικόνες (CR) σε ηλεκτρονική μορφή) οι οποίες αξιολογήθηκαν από δύο παρατηρητές και βασίστηκαν στην ορατότητα ορισμένων ανατομικών χαρακτηριστικών χρησιμοποιώντας μια πενταβάθμια κλίμακα. Οι ESDoutput τιμές αυξάνονται με την αύξηση του βάρους και κυμαίνονται από 16.8μGy σε 64.7μGy, με μέση τιμή 36μGy για όλες τις ακτινογραφίες. Ομοίως, οι ESDDAP τιμές κυμαίνονται από 14.8 μGy σε 48.5 μGy, με μέση τιμή 29 μGy. Αναλυτικά, η μέση τιμή ESD για τις ψηφιακές (CR) εικόνες βρέθηκε 34.8μGy και για τις συμβατικές 36.9μGy. Η ESD για CR εικόνες έχει στατιστικά την ίδια συμπεριφορά με την ESD για SF εικόνες. Η πλειοψηφία των αποκτηθέντων τιμών είναι χαμηλότερες από τα Διαγνωστικά Επίπεδα Αναφοράς που έχουν προταθεί από την Επιτροπή της Ευρωπαϊκής Ένωσης (CEC: 80μGy) και το National Radiological Protection Board (NRPB: 50μGy) για προσθοπίσθιες ακτινογραφίες θώρακος νεογνών. Η αξιολόγηση της ποιότητας της εικόνας αποκάλυψε την δυνατότητα επίτευξης μιας διαγνωστικά ικανοποιητικής εικόνας χρησιμοποιώντας τόσο χαμηλές όσο και υψηλές τάσεις, με τις τελευταίες να οδηγούν σε μείωση των επιφανειακών δόσεων (ESDs). Τα αποτελέσματα δείχνουν ότι η χρήση τεχνικών υψηλής τάσης μπορούν να οδηγήσουν σε περαιτέρω μείωση των δόσεων στα νεογνά, χωρίς να υποβαθμίζεται η ποιότητα της εικόνας, τα οποία βασίζονται στην απαίτηση καθορισμού τυποποιημένων πρωτοκόλλων εξέτασης για ακτινογραφίες σε νεογνά σε σχέση με το βάρος τους. 2013-07-26T09:13:21Z 2013-07-26T09:13:21Z 2013-04-16 2013-07-26 Thesis http://hdl.handle.net/10889/6243 en Η ΒΚΠ διαθέτει αντίτυπο της διατριβής σε έντυπη μορφή στο βιβλιοστάσιο διδακτορικών διατριβών που βρίσκεται στο ισόγειο του κτιρίου της. 0 application/pdf |