Study of small animal PET imaging optimization

The hybrid imaging combined by the positron emission (PET: Positron emission Tomography) and computed tomography (CT), PET/CT it is consider to be a very promising technology in medicine. The total time required for a PET imaging, is the sum of the acquisition time in PET procedure, and the scan tim...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριος συγγραφέας: Φώτος, Νικόλαος
Άλλοι συγγραφείς: Κωσταρίδου, Ελένη
Μορφή: Thesis
Γλώσσα:English
Έκδοση: 2016
Θέματα:
Διαθέσιμο Online:http://hdl.handle.net/10889/9800
id nemertes-10889-9800
record_format dspace
institution UPatras
collection Nemertes
language English
topic Positron emission tomography
NEMA protocol
Τομογραφία εκπομπής ποζιτρονίων
Πρωτόκολλο ΝΕΜΑ
616.075 75
spellingShingle Positron emission tomography
NEMA protocol
Τομογραφία εκπομπής ποζιτρονίων
Πρωτόκολλο ΝΕΜΑ
616.075 75
Φώτος, Νικόλαος
Study of small animal PET imaging optimization
description The hybrid imaging combined by the positron emission (PET: Positron emission Tomography) and computed tomography (CT), PET/CT it is consider to be a very promising technology in medicine. The total time required for a PET imaging, is the sum of the acquisition time in PET procedure, and the scan time in CT procedure. In clinical task, the positron emission tomography follows a variety of acquisition time protocols for the PET procedure, depending on the pathological issue, the organ, and the size of the patient. According to our literature research, it is introduced that there is not an optimum acquisition time for PET. Most of the protocols in preclinical task, introduce methodologies referring to the procedure of an experiment applied by a micro-PET/CT, and the studies are focused in evaluating the performance between different PET/CT systems. The Biomedical Research Foundation of Academy of Athens, in June 2014, added to its facilities, a brand new small animal PET/CT, the nanoScan of Mediso S.A. The aim of this thesis, is to evaluate the performance and stability of the new micro-PET/CT system, for various acquisition times, and the evaluation of an optimum acquisition time in preclinical task. This effort is focused on the investigation of the effect of acquisition time in image quality. Two experiments were performed, the one with phantom, and a second with mice. In addition, a Matlab code, was developed, for all the experiments, for recording and processing measurements of image quality characteristics. The Matlab results are in agreement with the System’s software. The phantom study, focused on the evaluation of performance of the systems from the scope of image quality, hence to ensure the stability of the new system over the time. Three scannings were performed with the same phantom, without changing the acquisition and reconstruction parameters. This was an effort for evaluating the precision of our measurements. For the image reconstruction in phantom studies so as in animal studies, was used the reconstruction algorithm OSEM 3D, with 4 iteration – 4 Subjects, in low Regularization level. The guide to our experiment was the NEMA-NU4 2008, using the IQ-Phantom as an object of study, and a radionuclide 18F, with a 3.7 MBq initial activity. It was followed an acquisition time method of 100 min List-Mode, divided in five time frames of 10,15,20,25, and 30 min, for which, five reconstruction was applied, by alternating the order of the frames, in a duration of 100 min List –Mode. In the phantom experiment, the stability of the system was evaluated by the reaction of the average activity concentration over the time, also the noise of the reconstructed image over the time was calculated, in the uniform region of the IQ-Phantom. Particularly, the average activity concentration found approximately equal to 191 KBq/ml, with a percentage standard deviation %STD ~4%. The results are in agreement with the NEMA protocol and the literature [42]. The dependence of average activity concentration from the total time acquisition, was displayed in diagrams (Average Activity Concentration vs Total Time Acquisition) for all of the reconstruction sets. The average activity concentration was not affected dramatically over the time. The %STD, it is an important characteristic of uniformity quality of the reconstructed image, and is indicative of the noise. Furthermore, the graphs %STD vs Total Time acquisition, presented that the noise is decreasing while the acquisition time increasing, a condition that it is expected. In addition the recovery coefficients were defined by the ratio of the measured activity concentration in the Rods’ region divided by the average activity concentration in the uniform region, and it ranges 0<RC≤1, with an ideal value equal to one RC=1. Indicatively, an average of the values are 0.04, 0.3, 0.7, 0.85, 0.9 for the rods with diameter of 1mm, 2mm, 3mm, 4mm, 5mm representatively and 10 mm long (z-axis) each. According to the characteristic curves of RC vs Rod diameter, for the five time frames, it is obvious that each curve overlap the other, and this encourage us to say that the RC is not differentiated significantly from 10 min to 30 min acquisition frame. Moreover, the Spill-Over ratio was defined by the ratio of the average measured activity of the cold region divided by the average activity concentration in the uniform region, and the values are reported as 0.11 for the water region and 0.12 for the air region. SOR ranges 0<SOR<1, with and ideal value SOR=0 The SOR values did not show significant differentiation over the time. The scope of the animal studies, is to evaluate the effect of acquisition time on image quality, by calculating the Standardized Uptake Value (SUV), for three different acquisition frames. Six experiments were performed, working on six mice with melanoma, which were injected with an 18F-FDG solution. The acquisition method was a 3D dynamic scan in a 30 min List-Mode. Consequently, three different reconstructions were performed, one for the first 10 min, a second for the first 20 min and a third for the 30 min, in the List-mode of 30 min. For the three reconstructions there was a semi quantitative analysis, by calculating the following SUVs of the reconstructed image: the max value SUVmax of the VOI, and four SUVsmean that were calculated by applying a threshold of 10%, 40%, 50% and 60% to the SUVmax. Finally, three population were created by the SUVs of the six mice, for the three reconstructions (10 min, 20 min, 30 min), and a Wilcoxon-Test was performed. The Wilcoxon-Test concluded that the three population are significant equal in the 5% significance level. Hence, the different acquisition time of 10, 20, and 30 min do not occur differentiation on the SUV.
author2 Κωσταρίδου, Ελένη
author_facet Κωσταρίδου, Ελένη
Φώτος, Νικόλαος
format Thesis
author Φώτος, Νικόλαος
author_sort Φώτος, Νικόλαος
title Study of small animal PET imaging optimization
title_short Study of small animal PET imaging optimization
title_full Study of small animal PET imaging optimization
title_fullStr Study of small animal PET imaging optimization
title_full_unstemmed Study of small animal PET imaging optimization
title_sort study of small animal pet imaging optimization
publishDate 2016
url http://hdl.handle.net/10889/9800
work_keys_str_mv AT phōtosnikolaos studyofsmallanimalpetimagingoptimization
AT phōtosnikolaos meletēbeltistopoiēsēstomographiaspetmikrōnzōōn
_version_ 1771297279438749696
spelling nemertes-10889-98002022-09-05T20:25:19Z Study of small animal PET imaging optimization Μελέτη βελτιστοποίησης τομογραφίας PET μικρών ζώων Φώτος, Νικόλαος Κωσταρίδου, Ελένη Κωσταρίδου, Ελένη Παναγιωτάκης, Γεώργιος Αναστάσιος, Γαιτάνης Fotos, Nikolaos Positron emission tomography NEMA protocol Τομογραφία εκπομπής ποζιτρονίων Πρωτόκολλο ΝΕΜΑ 616.075 75 The hybrid imaging combined by the positron emission (PET: Positron emission Tomography) and computed tomography (CT), PET/CT it is consider to be a very promising technology in medicine. The total time required for a PET imaging, is the sum of the acquisition time in PET procedure, and the scan time in CT procedure. In clinical task, the positron emission tomography follows a variety of acquisition time protocols for the PET procedure, depending on the pathological issue, the organ, and the size of the patient. According to our literature research, it is introduced that there is not an optimum acquisition time for PET. Most of the protocols in preclinical task, introduce methodologies referring to the procedure of an experiment applied by a micro-PET/CT, and the studies are focused in evaluating the performance between different PET/CT systems. The Biomedical Research Foundation of Academy of Athens, in June 2014, added to its facilities, a brand new small animal PET/CT, the nanoScan of Mediso S.A. The aim of this thesis, is to evaluate the performance and stability of the new micro-PET/CT system, for various acquisition times, and the evaluation of an optimum acquisition time in preclinical task. This effort is focused on the investigation of the effect of acquisition time in image quality. Two experiments were performed, the one with phantom, and a second with mice. In addition, a Matlab code, was developed, for all the experiments, for recording and processing measurements of image quality characteristics. The Matlab results are in agreement with the System’s software. The phantom study, focused on the evaluation of performance of the systems from the scope of image quality, hence to ensure the stability of the new system over the time. Three scannings were performed with the same phantom, without changing the acquisition and reconstruction parameters. This was an effort for evaluating the precision of our measurements. For the image reconstruction in phantom studies so as in animal studies, was used the reconstruction algorithm OSEM 3D, with 4 iteration – 4 Subjects, in low Regularization level. The guide to our experiment was the NEMA-NU4 2008, using the IQ-Phantom as an object of study, and a radionuclide 18F, with a 3.7 MBq initial activity. It was followed an acquisition time method of 100 min List-Mode, divided in five time frames of 10,15,20,25, and 30 min, for which, five reconstruction was applied, by alternating the order of the frames, in a duration of 100 min List –Mode. In the phantom experiment, the stability of the system was evaluated by the reaction of the average activity concentration over the time, also the noise of the reconstructed image over the time was calculated, in the uniform region of the IQ-Phantom. Particularly, the average activity concentration found approximately equal to 191 KBq/ml, with a percentage standard deviation %STD ~4%. The results are in agreement with the NEMA protocol and the literature [42]. The dependence of average activity concentration from the total time acquisition, was displayed in diagrams (Average Activity Concentration vs Total Time Acquisition) for all of the reconstruction sets. The average activity concentration was not affected dramatically over the time. The %STD, it is an important characteristic of uniformity quality of the reconstructed image, and is indicative of the noise. Furthermore, the graphs %STD vs Total Time acquisition, presented that the noise is decreasing while the acquisition time increasing, a condition that it is expected. In addition the recovery coefficients were defined by the ratio of the measured activity concentration in the Rods’ region divided by the average activity concentration in the uniform region, and it ranges 0<RC≤1, with an ideal value equal to one RC=1. Indicatively, an average of the values are 0.04, 0.3, 0.7, 0.85, 0.9 for the rods with diameter of 1mm, 2mm, 3mm, 4mm, 5mm representatively and 10 mm long (z-axis) each. According to the characteristic curves of RC vs Rod diameter, for the five time frames, it is obvious that each curve overlap the other, and this encourage us to say that the RC is not differentiated significantly from 10 min to 30 min acquisition frame. Moreover, the Spill-Over ratio was defined by the ratio of the average measured activity of the cold region divided by the average activity concentration in the uniform region, and the values are reported as 0.11 for the water region and 0.12 for the air region. SOR ranges 0<SOR<1, with and ideal value SOR=0 The SOR values did not show significant differentiation over the time. The scope of the animal studies, is to evaluate the effect of acquisition time on image quality, by calculating the Standardized Uptake Value (SUV), for three different acquisition frames. Six experiments were performed, working on six mice with melanoma, which were injected with an 18F-FDG solution. The acquisition method was a 3D dynamic scan in a 30 min List-Mode. Consequently, three different reconstructions were performed, one for the first 10 min, a second for the first 20 min and a third for the 30 min, in the List-mode of 30 min. For the three reconstructions there was a semi quantitative analysis, by calculating the following SUVs of the reconstructed image: the max value SUVmax of the VOI, and four SUVsmean that were calculated by applying a threshold of 10%, 40%, 50% and 60% to the SUVmax. Finally, three population were created by the SUVs of the six mice, for the three reconstructions (10 min, 20 min, 30 min), and a Wilcoxon-Test was performed. The Wilcoxon-Test concluded that the three population are significant equal in the 5% significance level. Hence, the different acquisition time of 10, 20, and 30 min do not occur differentiation on the SUV. Η υβριδική απεικόνιση, ποζιτρονιακής εκπομπής (PET: Positron Emission Tomography) και υπολογιστικής τομογραφίας (CT: Computed Tomography), (PET/CT), αποτελεί μια πολλά υποσχόμενη τεχνολογία για την ιατρική. Ο συνολικός χρόνος εξέτασης της ποζιτρονικής τομογραφίας είναι άθροισμα του χρόνου λήψης δεδομένων PET, και χρόνου σάρωσης CT. Σε κλινικό επίπεδο, η ποζιτρονιακή τομογραφία συνοδεύεται από διάφορα πρωτόκολλα χρόνου λήψης δεδομένων PET, αναλόγως την πάθηση, το όργανο και το μέγεθος του ασθενούς. Το πρόβλημα που προέκυψε από τη βιβλιογραφική έρευνα είναι ότι σε προκλινικό επίπεδο, δεν παρουσιάζεται κάποιος βέλτιστος χρόνος λήψης δεδομένων PET. Τα περισσότερα πρωτόκολλα στην προκλινική έρευνα παρουσιάζουν μεθοδολογία διεξαγωγής πειραμάτων με τη χρήση micro-PET/CT, και οι μελέτες που έχουν γίνει αποσκοπούν στην σύγκριση διαφορετικών συστημάτων PET/CT μεταξύ τους. To Ίδρυμα Ιατροβιολογικών Ερευνών της Ακαδημίας Αθηνών πρόσθεσε στον εξοπλισμό του τον Ιούνιο του 2014 ένα καινούργιο ποζιτρονικό τομογράφο μικρών ζώων nanoScan της Mediso S.A. Στόχος λοιπόν της παρούσας εργασίας, είναι ο έλεγχος απόδοσης και σταθερότητας του καινούργιου τομογράφου, για διάφορους χρόνους λήψης δεδομένων, και η εύρεση ενός βέλτιστου χρόνου λήψης δεδομένων στην προκλινική έρευνα. Η προσπάθεια αυτή επικεντρώθηκε στη μελέτη του αν η μείωση του χρόνου λήψης δεδομένων επιφέρει αλλοίωση στη ποιότητα της ανακατασκευασμένης εικόνας. Πραγματοποιήθηκαν δύο πειράματα το πρώτο αφορούσε πείραμα με ομοίωμα , και το δεύτερο πείραμα σε πειραματόζωα. Επίσης, για την καταγραφή και επεξεργασία μετρήσεων χαρακτηριστικών ποιότητας εικόνας αναπτύχθηκε κώδικας στη MatLab, για όλα τα πειράματα, τα αποτελέσματα του οποίου ήρθαν σε συμφωνία με το λογισμικό του συστήματος. Σκοπός του πειράματος με ομοίωμα είναι να εκτιμηθούν οι επιδόσεις του μηχανήματος οσον αφορά την ποιότητα της εικόνας, καθώς και να διαπιστώσουμε ότι υπάρχει σταθερότητα του μηχανήματος στη διάρκεια του χρόνου. Πραγματοποιήθηκαν τρείς (3) σαρώσεις (Scannings) του πειράματος με το ίδιο ομοίωμα κρατώντας όλες τις παραμέτρους καταγραφής και ανακατασκευής ίδιες , όπου αποτέλεσε μία προσπάθεια εκτίμησης της επαναληψιμότητας των μετρήσεων. Για την ανακατασκευή των εικόνων τόσο στα πειράματα με ομοίωμα όσο και στα κλινικά πειράματα χρησιμοποιήθηκε ο αλγόριθμος ανακατασκευής OSEM 3D, με 4 Iteration – 4 Subsets, σε low Regularization level. Οδηγός στο πείραμά μας, ήταν το πρωτόκολλο της NEMA-NU 4 2008, χρησιμοποιώντας για αντικείμενο εξέτασης το IQ phantom NU-4, και ραδιοϊσότοπο 18F, με αρχική ενεργότητα 3.7 MBq. Ακολουθήθηκε μία τεχνική χρόνου λήψης δεδομένων 100 λεπτών σε List –mode, το οποίο μοιράστηκε σε 5 χρονικά στιγμιότυπα (Frames) 10, 15, 20,25, και 30 λεπτών και για τα οποία έγινε ανακατασκευή (Reconstruction) και επανάληψη αυτής με διαφορετική σειρά των χρονικών στιγμιοτύπων κατά τη διάρκεια του χρόνου λήψης των 100 λεπτών. Σε αυτό το πείραμα εκτιμήθηκε η σταθερότητα του μηχανήματος μέσω της μέσης συγκέντρωσης ενεργότητας (Average activity Concentration) στη διάρκεια του χρόνου, αλλά και ο θόρυβος της ανακατασκευασμένης εικόνας στη διάρκεια του χρόνου, στην περιοχή ομοιογένειας(Uniformity region) του IQ Phantom. Συγκεκριμένα η μέσης τιμής της συγκέντρωσης της ενεργότητας (Average Activity Concentration) βρέθηκε κατά μέσο όρο περίπου ίση με 191 kBq/ml, με μία αρκετά ικανοποιητική επι της εκατό τυπική απόκλιση ~4%. Τα αποτελέσματα έρχονται σε συμφωνία με το πρωτόκολλο της ΝΕΜΑ, αλλά και με τη διεθνή βιβλιογραφία [42]. Η συσχέτιση του Average Activity Concentration με το χρόνο αποτυπώθηκε σε διαγράμματα και για τα πέντε σετ ανακατασκευής, όπου δεν εμφανίστηκε κάποια σημαντική διαφοροποίηση. Η επι τοις εκατό τυπική απόκλιση %STD, αποτελεί σημαντικό χαρακτηριστικό ποιότητας ομοιογένειας της ανακατασκευασμένης εικόνας, και αποτυπώνει το θόρυβο που υπάρχει σε αυτή. Από γραφική του %STD σε συνάρτηση με το χρόνο, βρέθηκε το αναμενόμενο, ο θόρυβος να μειώνεται με την αύξηση του χρόνου λήψης δεδομένων. Εκτιμήθηκαν επίσης τα recovery coefficients (RC), μέσω του λόγου της μέγιστης συγκέντρωσης ενεργότητας στις περιοχές των ραβδιδίων (Rods’s region) προς το Average Activity Concentration του IQ Phantom ,με το RC να κυμαίνεται 0<RC≤1, με ιδανική τιμή του RC=1. Ενδεικτικά, βρέθηκε κατά μέσο όρο περίπου ίσο με 0.04, 0.3, 0.7, 0.85, 0.9 για πηγές ακτινοβολίας (Rods) διαμέτρου 1mm, 2mm, 3mm, 4mm, 5mm αντιστοίχως και μήκους 10mm. Από τις χαρακτηριστικές καμπύλες του Recovery Coefficients σε συνάρτηση με το μέγεθος της πηγής (εδώ η διάμετρος των Rods), για τα πέντε χρονικά στιγμιότυπα, είναι φανερό ότι η μία επικαλύπτει την άλλη, ενθαρρύνοντας μας να πούμε ότι, το RC δε διαφοροποιείται σημαντικά αν μειωθεί ο χρόνος λήψης δεδομένων ακόμα και στα 10 λεπτά. Επίσης εκτιμήθηκε το Spill-Over ratio (SOR), μέσω του υπολογισμού του λόγου της μέσης τιμής της ενεργότητας της μη ραδιενεργής περιοχής προς το Average Activity Concentration της ομοιογενούς περιοχής, με αρκετά ικανοποιητικά νούμερα, 0.11 για την περιοχή του νερού και 0.12 για την περιοχή του αέρα. Επίσης, δεν παρουσιάστηκε σημαντική διαφοροποίηση σε συνάρτηση με το χρόνο λήψης δεδομένων, η τιμή του SOR κυμαίνεται 0<SOR<1, με ιδανική τιμή SOR=0. Σκοπός των κλινικών πειραμάτων είναι να εξεταστεί αν ο χρόνος λήψης δεδομένων επηρέαζει την ποιότητα της ανακατασκευασμένης εικόνας, μέσω υπολογισμού του βαθμού πρόσληψης του ραδιοφαρμάκου (Standardized Uptake Value-SUV), για τρείς (3) χρόνους λήψης δεδομένων. Ακολούθησαν πειράματα με μύες στα οποία χορηγήθηκαν 18F-FDG. Επιλέχθηκαν 6 μύες με μελάνωμα. Η τεχνική λήψης δεδομένων που ακολουθήθηκε ήταν δυναμική καταγραφή σε List-Mode 30 λεπτών, και 3 διαφορετικές ανακατασκευές, μια για τα πρώτα 10 λέπτα, μία δεύτερη για τα πρώτα 20 λεπτά και μία τρίτη για τα 30 λεπτά. Και για τις τρείς ανακατασκευές έγινε (ημι)-ποσοτική ανάλυση υπολογίζοντας τα εξής SUVs στην ανακατασκευασμένη εικόνα: τη μέγιστη τιμή SUVmax του όγκου ενδιαφέροντός (VOI), καθώς και τέσσερα SUVmean, τα οποία υπολογίστηκαν με κατωφλίωση 10%,40%,50% και 60% επί του SUVmax. Τέλος δημιουργήθηκαν τρείς(3) πληθυσμοί από τα SUV των 6 ποντικιών για τις τρείς(3) ανακατασκευές (10min, 20min, 30min), και πραγματοποιήθηκε Wilcoxon –Test. Το Wilcoxon-Test έδειξε ότι οι τρείς πληθυσμοί μεταξύ τους δεν παρουσιάζουν διαφοροποίηση στην ενδιάμεσο τιμή τους, στη στάθμη σημαντικότητας 5%. Αυτό συνεπάγεται ότι ο χρόνος λήψης δεδομένων δεν επιφέρει σημαντικές αλλαγές στη διαφοροποίηση του SUV. 2016-12-15T15:44:30Z 2016-12-15T15:44:30Z 2016-05-18 Thesis http://hdl.handle.net/10889/9800 en 6 application/pdf