Breast dose in digital mammography

Breast cancer is the leading type of cancer in women, with almost 1.000.000 cases, annually. In Greece, 4.500 new cases every year are reported, while it is estimated that 1 out of 8 women worldwide will develop breast cancer some time in her life. Due to the accelerating rate of the technological e...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Κύριος συγγραφέας: Λεκάτου, Αριστέα
Άλλοι συγγραφείς: Παναγιωτάκης, Γιώργος
Μορφή: Thesis
Γλώσσα:English
Έκδοση: 2017
Θέματα:
Διαθέσιμο Online:http://hdl.handle.net/10889/9954
id nemertes-10889-9954
record_format dspace
institution UPatras
collection Nemertes
language English
topic Medical physics
Dosimetry
Ιατρική φυσική
Δοσιμετρία
618.190 757 2
spellingShingle Medical physics
Dosimetry
Ιατρική φυσική
Δοσιμετρία
618.190 757 2
Λεκάτου, Αριστέα
Breast dose in digital mammography
description Breast cancer is the leading type of cancer in women, with almost 1.000.000 cases, annually. In Greece, 4.500 new cases every year are reported, while it is estimated that 1 out of 8 women worldwide will develop breast cancer some time in her life. Due to the accelerating rate of the technological evolution and the need for the phenomenon, the mammography has evolved into the most common diagnostic tool for the early detection of breast cancer. However, the patient dose must be kept as low as reasonably achievable and it is inspected by the Diagnostic Reference Levels (DRLs). The purpose of this study is to obtain patient dose data from screening mammography examinations conducted at the University Hospital of Patras, in order to establish institutional DRLs and to compare them with the corresponding national and European values. Particularly, three hundred women, 40-80 years old, participated in the study. All mammographic examinations were performed with a Hologic Selenia Dimensions digital mammography unit. The patient characteristics (age, weight, height), exposure and technical parameters (tube voltage, tube load, target/filter material, projections, compressed breast thickness (CBT), compression force), entrance surface dose (ESD) and average glandular dose (AGD) were recorded. Moreover, data analysis and study were conducted relating the dose with the other parameters and then the DRLs were estimated for CBT 55-65 mm for all projections, craniocaudal (CC) and oblique (MLO), as the 75th percentile of dose distributions. The local dose levels proved to be lower than the corresponding national and European values. The DRLs reported, could contribute in the performance evaluation of the local practice and in the effort for further optimization and radiation protection in screening mammography.
author2 Παναγιωτάκης, Γιώργος
author_facet Παναγιωτάκης, Γιώργος
Λεκάτου, Αριστέα
format Thesis
author Λεκάτου, Αριστέα
author_sort Λεκάτου, Αριστέα
title Breast dose in digital mammography
title_short Breast dose in digital mammography
title_full Breast dose in digital mammography
title_fullStr Breast dose in digital mammography
title_full_unstemmed Breast dose in digital mammography
title_sort breast dose in digital mammography
publishDate 2017
url http://hdl.handle.net/10889/9954
work_keys_str_mv AT lekatouaristea breastdoseindigitalmammography
AT lekatouaristea dosēmastoustēnpsēphiakēmastographia
_version_ 1771297154518745088
spelling nemertes-10889-99542022-09-05T05:38:34Z Breast dose in digital mammography Δόση μαστού στην ψηφιακή μαστογραφία Λεκάτου, Αριστέα Παναγιωτάκης, Γιώργος Κωσταρίδου, Ελένη Καλογεροπούλου, Χριστίνα Lekatou, Aristea Medical physics Dosimetry Ιατρική φυσική Δοσιμετρία 618.190 757 2 Breast cancer is the leading type of cancer in women, with almost 1.000.000 cases, annually. In Greece, 4.500 new cases every year are reported, while it is estimated that 1 out of 8 women worldwide will develop breast cancer some time in her life. Due to the accelerating rate of the technological evolution and the need for the phenomenon, the mammography has evolved into the most common diagnostic tool for the early detection of breast cancer. However, the patient dose must be kept as low as reasonably achievable and it is inspected by the Diagnostic Reference Levels (DRLs). The purpose of this study is to obtain patient dose data from screening mammography examinations conducted at the University Hospital of Patras, in order to establish institutional DRLs and to compare them with the corresponding national and European values. Particularly, three hundred women, 40-80 years old, participated in the study. All mammographic examinations were performed with a Hologic Selenia Dimensions digital mammography unit. The patient characteristics (age, weight, height), exposure and technical parameters (tube voltage, tube load, target/filter material, projections, compressed breast thickness (CBT), compression force), entrance surface dose (ESD) and average glandular dose (AGD) were recorded. Moreover, data analysis and study were conducted relating the dose with the other parameters and then the DRLs were estimated for CBT 55-65 mm for all projections, craniocaudal (CC) and oblique (MLO), as the 75th percentile of dose distributions. The local dose levels proved to be lower than the corresponding national and European values. The DRLs reported, could contribute in the performance evaluation of the local practice and in the effort for further optimization and radiation protection in screening mammography. Ο καρκίνος του μαστού αποτελεί την πιο συχνή μορφή καρκίνου μεταξύ των γυναικών, με περίπου 1.000.000 κρούσματα κάθε χρόνο, παγκοσμίως. Στην Ελλάδα αναφέρονται 4.500 περίπου νέες περιπτώσεις ετησίως, ενώ εκτιμάται ότι 1 στις 8 γυναίκες παγκοσμίως θα παρουσιάσει καρκίνο του μαστού σε κάποια φάση της ζωής της. Με την ταχεία εξέλιξη της τεχνολογίας και την ανάγκη για την καταπολέμηση του φαινομένου, εξελίχθηκε ο μαστογράφος σε ένα από τα πιο σημαντικά ακτινογραφικά εργαλεία για την έγκαιρη διάγνωση του καρκίνου. Ωστόσο, η δόση στον μαστό από μια μαστογραφική εξέταση πρέπει να είναι τόσο χαμηλή όσο είναι λογικά εφικτό και και τα επίπεδα της ελέγχονται από τα Διαγνωστικά Επίπεδα Αναφοράς (Δ.Ε.Α.). Σκοπός της εργασίας αυτής είναι η εύρεση των δόσεων στους εξεταζόμενους κατά την διάρκεια μιας μαστογραφικής εξέτασης προσυμπτωματικού ελέγχου, που διεξήχθη στο Πανεπιστημιακό Γενικό Νοσοκομείο Πατρών (Π.Γ.Ν.Π) ώστε να καθιερωθούν νοσοκομειακά Δ.Ε.Α. και να συγκριθούν με τις αντίστοιχες εθνικές και ευρωπαικές τιμές. Συγκεκριμένα, πραγματοποιήθηκε έρευνα της απορροφούμενης δόσης κατά την μαστογραφική εξέταση προσυμπτωματικού ελέγχου, 300 γυναικών, ηλικίας 40 έως 80 ετών, στο Π.Γ.Ν.Π εν έτει 2016. Όλες οι μαστογραφίες έγιναν με τον ψηφιακό μαστογράφο Hologic Selenia Dimensions. Τα δεδομένα που καταγράφηκαν και λήφθηκαν ψηφιακά ήταν χαρακτηριστικά του ασθενούς (ηλικία, βάρος, ύψος) , παράγοντες έκθεσης και τεχνικές παράμετροι (τάση, φορτίο λυχνίας, υλικό στόχου/φίλτρου, προβολές, πάχος συμπιεσμένου μαστού, δύναμη συμπίεσης), δόση εισόδου και μέση αδενική δόση. Πραγματοποιήθηκε ανάλυση των δεδομένων και μελέτη της επίδρασης αυτών σε σχέση με την δόση. Έπειτα, υπολογίστηκαν τα νοσοκομειακά Δ.Ε.Α. στο 75% της κατανομής της δόσης για πάχος συμπιεσμένου μαστού 55-65 mm για τις όλες τις λήψεις. Έγινε σύγκριση των τιμών με τα εθνικά Δ.Ε.Α και με τις ευρωπαικές τιμές και απεδείχθη ότι τα επίπεδα δόσης της έρευνας αυτής είναι, κατά κύριο λόγο, χαμηλότερα από τα υπόλοιπα. Τα Δ.Ε.Α. που υπολογίστηκαν θα μπορούσαν να συνεισφέρουν στην αξιολόγηση του μηχανήματος και της πρακτικής του Π.Γ.Ν.Π, καθώς και στην προσπάθεια για περαιτέρω βελτιστοποίηση και ακτινοπροστασία στην ψηφιακή μαστογραφία. 2017-02-10T06:43:17Z 2017-02-10T06:43:17Z 2016-10-21 Thesis http://hdl.handle.net/10889/9954 en 0 application/pdf