id |
oapen-20.500.12657-85262
|
record_format |
dspace
|
spelling |
oapen-20.500.12657-852622023-11-21T02:29:05Z 380 kV Superconducting Fault Current Limiter Feasibility Study Noe, Mathias Humpert, Chistof De Sousa, Wescley Fink, Stefan Herzog, Friedhelm Huwer, Stefan Nießen, Marvin Pfaller, Sebastian Pöhler, Stephan Rodler, Tobias Schmid, André Arndt, Tabea economic feasibility; bifilar coil; high voltage; superconducting fault current limiter; superconductor; wirtschaftliche Machbarkeit; bifilare Spule; Hochspannung; supraleitender Strombegrenzer; Supraleiter bic Book Industry Communication::T Technology, engineering, agriculture::TH Energy technology & engineering::THR Electrical engineering In this study the technical and economic feasibility of a 380 kV, 5 kA resistive type superconducting fault current limiter was investigated. Conceptual designs were developed with superconducting tapes cooled by liquid nitrogen and arranged in bifilar coils. A cryostat was designed using FEM simulations taking into account the non-linear voltage distribution. For the complete system including current limiting reactors and cooling system, the investment and operation costs were calculated. 2023-11-20T14:06:23Z 2023-11-20T14:06:23Z 2023 book https://library.oapen.org/handle/20.500.12657/85262 eng Karlsruher Schriftenreihe zur Supraleitung application/pdf Attribution-ShareAlike 4.0 International 380-kv-superconducting-fault-current-limiter-feasibility-study.pdf https://doi.org/10.5445/KSP/1000161057 KIT Scientific Publishing 10.5445/KSP/1000161057 10.5445/KSP/1000161057 44e29711-8d53-496b-85cc-3d10c9469be9 37 168 open access
|
institution |
OAPEN
|
collection |
DSpace
|
language |
English
|
description |
In this study the technical and economic feasibility of a 380 kV, 5 kA resistive type superconducting fault current limiter was investigated. Conceptual designs were developed with superconducting tapes cooled by liquid nitrogen and arranged in bifilar coils. A cryostat was designed using FEM simulations taking into account the non-linear voltage distribution. For the complete system including current limiting reactors and cooling system, the investment and operation costs were calculated.
|
title |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
spellingShingle |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
title_short |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
title_full |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
title_fullStr |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
title_full_unstemmed |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
title_sort |
380-kv-superconducting-fault-current-limiter-feasibility-study.pdf
|
publisher |
KIT Scientific Publishing
|
publishDate |
2023
|
url |
https://doi.org/10.5445/KSP/1000161057
|
_version_ |
1799945280519405568
|