Gas insulated substations /

"Comprehensive reference covering all aspects of gas insulated substations including basic principles, technology, use & application, design, specification, testing and ownership issuesThis book provides an overview on the particular development steps of gas insulated high-voltage switchgea...

Πλήρης περιγραφή

Λεπτομέρειες βιβλιογραφικής εγγραφής
Μορφή: Ηλ. βιβλίο
Γλώσσα:English
Έκδοση: Chichester, West Sussex, United Kingdom : IEEE Press, Wiley, 2014.
Θέματα:
Διαθέσιμο Online:Full Text via HEAL-Link
LEADER 05676nam a2200649 4500
001 ocn876141194
003 OCoLC
005 20170124070047.4
006 m o d
007 cr |||||||||||
008 140407s2014 enk ob 001 0 eng
010 |a  2014013892 
040 |a DLC  |b eng  |e rda  |c DLC  |d YDX  |d N$T  |d E7B  |d DG1  |d IEEEE  |d YDXCP  |d OCLCF  |d OCLCO  |d COO  |d B24X7  |d RECBK  |d DEBBG  |d D6H  |d IAS  |d GrThAP 
020 |a 9781118694527 (ePub) 
020 |a 111869452X (ePub) 
020 |a 9781118694510 (Adobe PDF) 
020 |a 1118694511 (Adobe PDF) 
020 |z 9781118570722 (hardback) 
020 |a 9781118694534 (electronic bk.) 
020 |a 1118694538 (electronic bk.) 
020 |a 1118570723 
020 |a 9781118570722 
029 1 |a NZ1  |b 15753456 
029 1 |a NLGGC  |b 377369381 
029 1 |a NZ1  |b 15906982 
029 1 |a CHVBK  |b 334088003 
029 1 |a CHBIS  |b 010442109 
029 1 |a GBVCP  |b 814516564 
029 1 |a DEBBG  |b BV043396675 
035 |a (OCoLC)876141194 
042 |a pcc 
050 0 0 |a TK3441.G3 
072 7 |a TEC  |x 009070  |2 bisacsh 
082 0 0 |a 621.31/042  |2 23 
084 |a TEC008090  |2 bisacsh 
049 |a MAIN 
245 0 0 |a Gas insulated substations /  |c edited by Hermann J. Koch. 
264 1 |a Chichester, West Sussex, United Kingdom :  |b IEEE Press, Wiley,  |c 2014. 
300 |a 1 online resource. 
336 |a text  |2 rdacontent 
337 |a computer  |2 rdamedia 
338 |a online resource  |2 rdacarrier 
520 |a "Comprehensive reference covering all aspects of gas insulated substations including basic principles, technology, use & application, design, specification, testing and ownership issuesThis book provides an overview on the particular development steps of gas insulated high-voltage switchgear, and is based on the information given with the editor's tutorial. The theory is kept low only as much as it is needed to understand gas insulated technology, with the main focus of the book being on delivering practical application knowledge. It discusses some introductory and advanced aspects in the meaning of applications.The start of the book presents the theory of Gas Insulated Technology, and outlines reliability, design, safety, grounding and bonding, and factors for choosing GIS. The third chapter presents the technology, covering the following in detail: manufacturing, specification, instrument transformers, Gas Insulated Bus, and the assembly process. Next, the book goes into control and monitoring, which covers local control cabinet, bay controller, control schemes, and digital communication. Testing is explained in the middle of the book before installation and energization. Importantly, operation and maintenance is discussed. This chapter includes information on repair, extensions, retrofit or upgrade, and overloading. Finally applications are covered along with concepts of layout, typical layouts, mixed technology substations, and then other topics such as life cycle assessment, environmental impact, and project management. A one-stop, complete reference text on gas insulated substations (GIS), large-capacity and long-distance electricity transmission, which are of increasing importance in the power industry today Details advanced and basic material, accessible for both existing GIS users and those planning to adopt the technology Discusses both the practical and theoretical aspects of GIS Written by acknowledged GIS experts who have been involved in the development of the technology from the start "--  |c Provided by publisher. 
504 |a Includes bibliographical references and index. 
588 |a Description based on print version record and CIP data provided by publisher. 
505 8 |a 3150 A Indoor Double Bus GIS 8.3.5 115 kV and 1200 A Container Ring Bus GIS 8.3.6 115 kV and 2000 A Outdoor Single Bus GIS 8.3.7 345 kV and 4000 A Indoor Breaker and Half GIS 8.3.8 115 kV and 3150 A Indoor Ring Bus GIS 8.3.9 69 kV and 2000 A Indoor Ring Bus GIS 8.3.10 138 kV and 230 kV Outdoor Ring Bus GIS 8.3.11 500 kV and 4000 A/8000 A Indoor Breaker and Third GIS 8.3.12 69 kV and 1600 A Outdoor Single Bus GIS 8.3.13 69 kV and 2000 A Underground GIS Hermann Koch 8.4 GIS Case Study Public Service Electric and Gas Company -- New Jersey 230 kV, 80 kA Bergen Switching Station Peter Grossmann 8.5 Mobile GIS Hermann Koch 8.6 Mixed Technology Switchgear (MTS) Dave Solhtalab 8.7 Future Developments Hermann Koch 9 Other Topics 9.1 General Hermann Koch 9.2.1 Environmental Life Cycle Assessment Venkatesh Minisandram 9.2.2 GIS Environmental Impact Arnaud Ficheux 9.2.3 Environmental Impact Hermann Koch 9.3 Life Cycle Cost Analysis George Becker 9.4 Insulation Coordination Study Hermann Koch 9.5 Very Fast Transients Nobby Fujimoto 9.6 Project Scope Development Jorge Marquez 9.7 Risk-Based Asset Management of Gas-Insulated Substations and Equipment George Becker 9.8 Health and Safety Impact Hermann Koch 9.9 Electro Magnetic Field Hermann Koch 10 Conclusions Hermann Koch. 
650 0 |a Electric cables  |x Gas insulation. 
650 0 |a Electric substations. 
650 7 |a TECHNOLOGY & ENGINEERING / Electronics / Semiconductors.  |2 bisacsh 
650 7 |a Electric cables  |x Gas insulation.  |2 fast  |0 (OCoLC)fst00904501 
650 7 |a Electric substations.  |2 fast  |0 (OCoLC)fst00905909 
655 4 |a Electronic books. 
655 0 |a Electronic books. 
700 1 |a Koch, Hermann,  |d 1954-  |e editor of compilation. 
776 0 8 |i Print version:  |t Gas insulated substations  |d Chichester, West Sussex, United Kingdom : John Wiley & Sons Inc., 2014  |z 9781118570722  |w (DLC) 2014002202 
856 4 0 |u https://doi.org/10.1002/9781118694534  |z Full Text via HEAL-Link 
994 |a 92  |b DG1